REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2024-05-06-11|TLH-2024-06-18-97|2494484|26.71393, -81.56266|CLEW04|17-JUN-2024|09:45|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|7.6||ug/L|0.93|2.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494484|26.71393, -81.56266|CLEW04|17-JUN-2024|09:45|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|9.6||ug/L|0.68|2.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494484|26.71393, -81.56266|CLEW04|17-JUN-2024|09:45|02-JUL-2024|16:15|32218|Phaeophytin-a|2.9|I|ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494485|26.69315, 81.79630|ORANGE|17-JUN-2024|11:15|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|8.3||ug/L|0.93|2.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494485|26.69315, 81.79630|ORANGE|17-JUN-2024|11:15|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|11||ug/L|0.68|2.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494485|26.69315, 81.79630|ORANGE|17-JUN-2024|11:15|02-JUL-2024|16:15|32218|Phaeophytin-a|3.7||ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494486|26.70324, 81.80525|POPASH|17-JUN-2024|11:35|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|14||ug/L|0.93|2.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494486|26.70324, 81.80525|POPASH|17-JUN-2024|11:35|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|17||ug/L|0.68|2.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494486|26.70324, 81.80525|POPASH|17-JUN-2024|11:35|02-JUL-2024|16:15|32218|Phaeophytin-a|4.8||ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494487|26.65737, 81.89425|HANCOCK|17-JUN-2024|12:35|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|14||ug/L|0.93|2.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494487|26.65737, 81.89425|HANCOCK|17-JUN-2024|12:35|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|17||ug/L|0.68|2.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494487|26.65737, 81.89425|HANCOCK|17-JUN-2024|12:35|02-JUL-2024|16:15|32218|Phaeophytin-a|4.2||ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494488|26.64467, -81.87899|CLEW07|17-JUN-2024|13:00|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|8.3||ug/L|0.93|2.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494488|26.64467, -81.87899|CLEW07|17-JUN-2024|13:00|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|11||ug/L|0.68|2.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494488|26.64467, -81.87899|CLEW07|17-JUN-2024|13:00|02-JUL-2024|16:15|32218|Phaeophytin-a|3.8||ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SOROC|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494489|26.57761, -81.89881|WHISKEY|17-JUN-2024|10:50|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|8.4|A|ug/L|1.2|3.5|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Laboratory duplicate result is 1.9 I for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2024-05-06-11|TLH-2024-06-18-97|2494489|26.57761, -81.89881|WHISKEY|17-JUN-2024|10:50|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|9.9|A|ug/L|0.84|2.5|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Laboratory duplicate result is 1.9 I for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2024-05-06-11|TLH-2024-06-18-97|2494489|26.57761, -81.89881|WHISKEY|17-JUN-2024|10:50|02-JUL-2024|16:15|32218|Phaeophytin-a|1.9|I|ug/L|1.3|3.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Laboratory duplicate result is 1.9 I for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2024-05-06-11|TLH-2024-06-18-97|2494490|26.54335, -81.94011|CLEW09|17-JUN-2024|11:08|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|26||ug/L|0.93|2.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494490|26.54335, -81.94011|CLEW09|17-JUN-2024|11:08|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|30||ug/L|0.68|2.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494490|26.54335, -81.94011|CLEW09|17-JUN-2024|11:08|02-JUL-2024|16:15|32218|Phaeophytin-a|6.2||ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494491|26.52328, -82.00864|CLEW10|17-JUN-2024|11:40|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|21||ug/L|0.93|2.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494491|26.52328, -82.00864|CLEW10|17-JUN-2024|11:40|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|24||ug/L|0.68|2.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494491|26.52328, -82.00864|CLEW10|17-JUN-2024|11:40|02-JUL-2024|16:15|32218|Phaeophytin-a|3.6||ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494492|26.47219, -82.01621|CLEW11|17-JUN-2024|12:13|02-JUL-2024|16:15|32211|Chlorophyll-a, Corrected|9.3||ug/L|0.93|2.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494492|26.47219, -82.01621|CLEW11|17-JUN-2024|12:13|02-JUL-2024|16:15|32210|Chlorophyll-a, Uncorrected|10||ug/L|0.68|2.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2024-05-06-11|TLH-2024-06-18-97|2494492|26.47219, -82.01621|CLEW11|17-JUN-2024|12:13|02-JUL-2024|16:15|32218|Phaeophytin-a|1.1|I|ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|18-JUN-2024|14:49|SM 10150 B|SCCF|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data.