REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2016-01-11-39|TLH-2016-01-21-58|1764488|Winkler Canal @ Princton St|SD012016-1|20-JAN-2016|10:05|22-JAN-2016|06:30|310|Biochemical Oxygen Demand-5 Day|0.84|I|mg/L|0.20|2.0|||||SM 5210 B|B.Paswater / C.Link / D.Berger|Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2016-01-11-39|TLH-2016-01-21-58|1764489|Field Blank|SD012016-2|20-JAN-2016|10:11|22-JAN-2016|06:30|310|Biochemical Oxygen Demand-5 Day|0.20|U|mg/L|0.20|2.0|||||SM 5210 B|B.Paswater / C.Link / D.Berger|Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2016-01-11-39|TLH-2016-01-21-59|1764490|Winkler Canal @ Princton St|SD012016-1|20-JAN-2016|10:05|28-JAN-2016|09:20|32211|Chlorophyll-a, Corrected|0.63|I|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|21-JAN-2016|13:55|SM 10200 H (mod.)|B.Paswater / C.Link / D.Berger|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-01-11-39|TLH-2016-01-21-59|1764490|Winkler Canal @ Princton St|SD012016-1|20-JAN-2016|10:05|28-JAN-2016|09:20|32210|Chlorophyll-a, Uncorrected|0.82|I|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|21-JAN-2016|13:55|SM 10200 H (mod.)|B.Paswater / C.Link / D.Berger|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-01-11-39|TLH-2016-01-21-59|1764490|Winkler Canal @ Princton St|SD012016-1|20-JAN-2016|10:05|28-JAN-2016|09:20|32219|Chlorophyll/Phaeophytin Ratio|1.5|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|21-JAN-2016|13:55|SM 10200 H (mod.)|B.Paswater / C.Link / D.Berger|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-01-11-39|TLH-2016-01-21-59|1764490|Winkler Canal @ Princton St|SD012016-1|20-JAN-2016|10:05|28-JAN-2016|09:20|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|21-JAN-2016|13:55|SM 10200 H (mod.)|B.Paswater / C.Link / D.Berger|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-01-11-39|TLH-2016-01-21-59|1764491|Field Blank|SD012016-2|20-JAN-2016|10:11|28-JAN-2016|09:20|32211|Chlorophyll-a, Corrected|0.55|U|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|21-JAN-2016|13:55|SM 10200 H (mod.)|B.Paswater / C.Link / D.Berger|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-01-11-39|TLH-2016-01-21-59|1764491|Field Blank|SD012016-2|20-JAN-2016|10:11|28-JAN-2016|09:20|32210|Chlorophyll-a, Uncorrected|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|21-JAN-2016|13:55|SM 10200 H (mod.)|B.Paswater / C.Link / D.Berger|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-01-11-39|TLH-2016-01-21-59|1764491|Field Blank|SD012016-2|20-JAN-2016|10:11|28-JAN-2016|09:20|32219|Chlorophyll/Phaeophytin Ratio|1.1|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|21-JAN-2016|13:55|SM 10200 H (mod.)|B.Paswater / C.Link / D.Berger|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-01-11-39|TLH-2016-01-21-59|1764491|Field Blank|SD012016-2|20-JAN-2016|10:11|28-JAN-2016|09:20|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|21-JAN-2016|13:55|SM 10200 H (mod.)|B.Paswater / C.Link / D.Berger|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data.