REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2016-02-08-60|TLH-2016-02-09-36|1769777|ARBUCKLE BRANCH @ ARBUCKLE CREEK R|SD020816-1|08-FEB-2016|10:40|10-FEB-2016|09:20|310|Biochemical Oxygen Demand-5 Day|1.2|IV|mg/L|0.20|2.0|||||SM 5210 B|DANNY BERGER/COREY ANDERSON|Precision data is unavailable due to the small amount of analyte in the QC sample. Dilution water blank exceeds laboratory historical limit of 0.50 mg/L. RQ-2016-02-08-60|TLH-2016-02-09-36|1769778|ARBUCKLE CR. ABOVE MORGAN HOLE BY RAMP|SD020816-2|08-FEB-2016|12:50|10-FEB-2016|09:20|310|Biochemical Oxygen Demand-5 Day|1.2|IV|mg/L|0.20|2.0|||||SM 5210 B|DANNY BERGER/COREY ANDERSON|Precision data is unavailable due to the small amount of analyte in the QC sample. Dilution water blank exceeds laboratory historical limit of 0.50 mg/L. RQ-2016-02-08-60|TLH-2016-02-09-36|1769779|ARBUCKLE CREEK @ ARBUCKLE CR. ROAD|SD020816-3|08-FEB-2016|10:58|10-FEB-2016|09:20|310|Biochemical Oxygen Demand-5 Day|1.1|IV|mg/L|0.20|2.0|||||SM 5210 B|DANNY BERGER/COREY ANDERSON|Precision data is unavailable due to the small amount of analyte in the QC sample. Dilution water blank exceeds laboratory historical limit of 0.50 mg/L. RQ-2016-02-08-60|TLH-2016-02-09-37|1769780|ARBUCKLE BRANCH @ ARBUCKLE CREEK R|SD020816-1|08-FEB-2016|10:40|15-FEB-2016|14:35|32211|Chlorophyll-a, Corrected|1.2|I|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769780|ARBUCKLE BRANCH @ ARBUCKLE CREEK R|SD020816-1|08-FEB-2016|10:40|15-FEB-2016|14:35|32210|Chlorophyll-a, Uncorrected|1.9||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769780|ARBUCKLE BRANCH @ ARBUCKLE CREEK R|SD020816-1|08-FEB-2016|10:40|15-FEB-2016|14:35|32219|Chlorophyll/Phaeophytin Ratio|1.4|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769780|ARBUCKLE BRANCH @ ARBUCKLE CREEK R|SD020816-1|08-FEB-2016|10:40|15-FEB-2016|14:35|32218|Phaeophytin-a|1.0|I|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769781|ARBUCKLE CR. ABOVE MORGAN HOLE BY RAMP|SD020816-2|08-FEB-2016|12:50|15-FEB-2016|14:35|32211|Chlorophyll-a, Corrected|3.5||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769781|ARBUCKLE CR. ABOVE MORGAN HOLE BY RAMP|SD020816-2|08-FEB-2016|12:50|15-FEB-2016|14:35|32210|Chlorophyll-a, Uncorrected|5.3||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769781|ARBUCKLE CR. ABOVE MORGAN HOLE BY RAMP|SD020816-2|08-FEB-2016|12:50|15-FEB-2016|14:35|32219|Chlorophyll/Phaeophytin Ratio|1.4|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769781|ARBUCKLE CR. ABOVE MORGAN HOLE BY RAMP|SD020816-2|08-FEB-2016|12:50|15-FEB-2016|14:35|32218|Phaeophytin-a|2.8||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769782|ARBUCKLE CREEK @ ARBUCKLE CR. ROAD|SD020816-3|08-FEB-2016|10:58|15-FEB-2016|14:35|32211|Chlorophyll-a, Corrected|1.4|I|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769782|ARBUCKLE CREEK @ ARBUCKLE CR. ROAD|SD020816-3|08-FEB-2016|10:58|15-FEB-2016|14:35|32210|Chlorophyll-a, Uncorrected|2.2||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769782|ARBUCKLE CREEK @ ARBUCKLE CR. ROAD|SD020816-3|08-FEB-2016|10:58|15-FEB-2016|14:35|32219|Chlorophyll/Phaeophytin Ratio|1.4|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-02-08-60|TLH-2016-02-09-37|1769782|ARBUCKLE CREEK @ ARBUCKLE CR. ROAD|SD020816-3|08-FEB-2016|10:58|15-FEB-2016|14:35|32218|Phaeophytin-a|1.2||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|09-FEB-2016|13:40|SM 10200 H (mod.)|DANNY BERGER/COREY ANDERSON|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data.