REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2016-05-23-09|TLH-2016-06-02-78|1804176|HOWARD CREEK @ MYAKKA VALLEY TRAIL|G3SD060116-1|01-JUN-2016|09:25|14-JUN-2016|07:40|32211|Chlorophyll-a, Corrected|1.3|IJ|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Lab dup result is 1.5 for Chl:Ph Ratio, 1.1 IJ for Chl-a Corr, and 0.40 U for Phaeo-a. Precision data unavailable due to small amount of analyte in the QC sample. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804176|HOWARD CREEK @ MYAKKA VALLEY TRAIL|G3SD060116-1|01-JUN-2016|09:25|14-JUN-2016|07:40|32210|Chlorophyll-a, Uncorrected|1.5|A|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Lab dup result is 1.5 for Chl:Ph Ratio, 1.1 IJ for Chl-a Corr, and 0.40 U for Phaeo-a. Precision data unavailable due to small amount of analyte in the QC sample. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804176|HOWARD CREEK @ MYAKKA VALLEY TRAIL|G3SD060116-1|01-JUN-2016|09:25|14-JUN-2016|07:40|32219|Chlorophyll/Phaeophytin Ratio|1.5|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Lab dup result is 1.5 for Chl:Ph Ratio, 1.1 IJ for Chl-a Corr, and 0.40 U for Phaeo-a. Precision data unavailable due to small amount of analyte in the QC sample. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804176|HOWARD CREEK @ MYAKKA VALLEY TRAIL|G3SD060116-1|01-JUN-2016|09:25|14-JUN-2016|07:40|32218|Phaeophytin-a|0.44|I|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Lab dup result is 1.5 for Chl:Ph Ratio, 1.1 IJ for Chl-a Corr, and 0.40 U for Phaeo-a. Precision data unavailable due to small amount of analyte in the QC sample. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804177|INDIAN CREEK @ FRUITVILLE RD.|G3SD060116-2|01-JUN-2016|11:25|14-JUN-2016|07:40|32211|Chlorophyll-a, Corrected|0.71|IJ|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804177|INDIAN CREEK @ FRUITVILLE RD.|G3SD060116-2|01-JUN-2016|11:25|14-JUN-2016|07:40|32210|Chlorophyll-a, Uncorrected|4.2||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804177|INDIAN CREEK @ FRUITVILLE RD.|G3SD060116-2|01-JUN-2016|11:25|14-JUN-2016|07:40|32219|Chlorophyll/Phaeophytin Ratio|1.1|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804177|INDIAN CREEK @ FRUITVILLE RD.|G3SD060116-2|01-JUN-2016|11:25|14-JUN-2016|07:40|32218|Phaeophytin-a|5.7||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804178|HOWARD CREEK NE BRANCH LOT 185|G3SD060116-3|01-JUN-2016|09:35|14-JUN-2016|07:40|32211|Chlorophyll-a, Corrected|1.5|IJ|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804178|HOWARD CREEK NE BRANCH LOT 185|G3SD060116-3|01-JUN-2016|09:35|14-JUN-2016|07:40|32210|Chlorophyll-a, Uncorrected|1.8||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804178|HOWARD CREEK NE BRANCH LOT 185|G3SD060116-3|01-JUN-2016|09:35|14-JUN-2016|07:40|32219|Chlorophyll/Phaeophytin Ratio|1.5|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. Quality control failure(s) observed. See QA report for details. RQ-2016-05-23-09|TLH-2016-06-02-78|1804178|HOWARD CREEK NE BRANCH LOT 185|G3SD060116-3|01-JUN-2016|09:35|14-JUN-2016|07:40|32218|Phaeophytin-a|0.50|I|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|02-JUN-2016|12:55|SM 10200 H (mod.)|COREY ANDERSON, BEN PASWATER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. Quality control failure(s) observed. See QA report for details.