REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2016-06-06-16|TLH-2016-06-28-14|1811643|PEARL LAKE @ WESTSIDE|G4HL062016-9|27-JUN-2016|11:59|07-JUL-2016|08:25|32211|Chlorophyll-a, Corrected|2.2||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD| RQ-2016-06-06-16|TLH-2016-06-28-14|1811643|PEARL LAKE @ WESTSIDE|G4HL062016-9|27-JUN-2016|11:59|07-JUL-2016|08:25|32210|Chlorophyll-a, Uncorrected|2.3||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD| RQ-2016-06-06-16|TLH-2016-06-28-14|1811643|PEARL LAKE @ WESTSIDE|G4HL062016-9|27-JUN-2016|11:59|07-JUL-2016|08:25|32219|Chlorophyll/Phaeophytin Ratio|1.7|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD| RQ-2016-06-06-16|TLH-2016-06-28-14|1811643|PEARL LAKE @ WESTSIDE|G4HL062016-9|27-JUN-2016|11:59|07-JUL-2016|08:25|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD| RQ-2016-06-06-16|TLH-2016-06-28-14|1811644|PEARL LAKE @ CENTER|G4HL062016-10|27-JUN-2016|11:26|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|2.2||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811644|PEARL LAKE @ CENTER|G4HL062016-10|27-JUN-2016|11:26|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|2.2||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811644|PEARL LAKE @ CENTER|G4HL062016-10|27-JUN-2016|11:26|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.8|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811644|PEARL LAKE @ CENTER|G4HL062016-10|27-JUN-2016|11:26|11-JUL-2016|07:10|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811645|LAKE HENRY @ SE CORNER|G4HL062016-2|27-JUN-2016|10:15|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|16||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811645|LAKE HENRY @ SE CORNER|G4HL062016-2|27-JUN-2016|10:15|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|18||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811645|LAKE HENRY @ SE CORNER|G4HL062016-2|27-JUN-2016|10:15|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.6|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811645|LAKE HENRY @ SE CORNER|G4HL062016-2|27-JUN-2016|10:15|11-JUL-2016|07:10|32218|Phaeophytin-a|1.5|V|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811646|LAKE HENRY @ MIDDLE|G4HL062016-1|27-JUN-2016|10:00|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|19||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811646|LAKE HENRY @ MIDDLE|G4HL062016-1|27-JUN-2016|10:00|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|20||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811646|LAKE HENRY @ MIDDLE|G4HL062016-1|27-JUN-2016|10:00|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.7|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811646|LAKE HENRY @ MIDDLE|G4HL062016-1|27-JUN-2016|10:00|11-JUL-2016|07:10|32218|Phaeophytin-a|1.2|IV|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811647|LAKE HENRY @ NORTHSIDE|G4HL062016-5|27-JUN-2016|10:30|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|14||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Laboratory blank failure. Phaeophytin-a component result is >10 times blank. RQ-2016-06-06-16|TLH-2016-06-28-14|1811647|LAKE HENRY @ NORTHSIDE|G4HL062016-5|27-JUN-2016|10:30|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|20||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Laboratory blank failure. Phaeophytin-a component result is >10 times blank. RQ-2016-06-06-16|TLH-2016-06-28-14|1811647|LAKE HENRY @ NORTHSIDE|G4HL062016-5|27-JUN-2016|10:30|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.4|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Laboratory blank failure. Phaeophytin-a component result is >10 times blank. RQ-2016-06-06-16|TLH-2016-06-28-14|1811647|LAKE HENRY @ NORTHSIDE|G4HL062016-5|27-JUN-2016|10:30|11-JUL-2016|07:10|32218|Phaeophytin-a|9.0||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Laboratory blank failure. Phaeophytin-a component result is >10 times blank. RQ-2016-06-06-16|TLH-2016-06-28-14|1811648|LAKE HENRY @ SW SIDE|G4HL062016-4|27-JUN-2016|10:40|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|17||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811648|LAKE HENRY @ SW SIDE|G4HL062016-4|27-JUN-2016|10:40|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|19||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811648|LAKE HENRY @ SW SIDE|G4HL062016-4|27-JUN-2016|10:40|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.6|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811648|LAKE HENRY @ SW SIDE|G4HL062016-4|27-JUN-2016|10:40|11-JUL-2016|07:10|32218|Phaeophytin-a|2.2|V|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. Result V-qualified due to lab blank failure for Phaeophytin-a component only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811649|LAKE HENRY @ EASTSIDE|G4HL062016-3|27-JUN-2016|10:25|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|20|A|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Laboratory duplicate result is 1.2 I for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. Result is V-qualified due to laboratory blank failure for Phaeophytin-a only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811649|LAKE HENRY @ EASTSIDE|G4HL062016-3|27-JUN-2016|10:25|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|22|A|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Laboratory duplicate result is 1.2 I for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. Result is V-qualified due to laboratory blank failure for Phaeophytin-a only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811649|LAKE HENRY @ EASTSIDE|G4HL062016-3|27-JUN-2016|10:25|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.7|A||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Laboratory duplicate result is 1.2 I for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. Result is V-qualified due to laboratory blank failure for Phaeophytin-a only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811649|LAKE HENRY @ EASTSIDE|G4HL062016-3|27-JUN-2016|10:25|11-JUL-2016|07:10|32218|Phaeophytin-a|1.4|V|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Laboratory duplicate result is 1.2 I for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. Result is V-qualified due to laboratory blank failure for Phaeophytin-a only. RQ-2016-06-06-16|TLH-2016-06-28-14|1811650|PEARL LAKE @ NORTHSIDE|G4HL062016-6|27-JUN-2016|11:50|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|2.7||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811650|PEARL LAKE @ NORTHSIDE|G4HL062016-6|27-JUN-2016|11:50|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|2.9||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811650|PEARL LAKE @ NORTHSIDE|G4HL062016-6|27-JUN-2016|11:50|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.7|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811650|PEARL LAKE @ NORTHSIDE|G4HL062016-6|27-JUN-2016|11:50|11-JUL-2016|07:10|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811651|PEARL LAKE @ EASTSIDE|G4HL062016-7|27-JUN-2016|11:45|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|2.3||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811651|PEARL LAKE @ EASTSIDE|G4HL062016-7|27-JUN-2016|11:45|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|2.3||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811651|PEARL LAKE @ EASTSIDE|G4HL062016-7|27-JUN-2016|11:45|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.8|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811651|PEARL LAKE @ EASTSIDE|G4HL062016-7|27-JUN-2016|11:45|11-JUL-2016|07:10|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811652|PEARL LAKE @ SOUTHSIDE|G4HL062016-8|27-JUN-2016|11:35|11-JUL-2016|07:10|32211|Chlorophyll-a, Corrected|2.1||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811652|PEARL LAKE @ SOUTHSIDE|G4HL062016-8|27-JUN-2016|11:35|11-JUL-2016|07:10|32210|Chlorophyll-a, Uncorrected|2.1||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811652|PEARL LAKE @ SOUTHSIDE|G4HL062016-8|27-JUN-2016|11:35|11-JUL-2016|07:10|32219|Chlorophyll/Phaeophytin Ratio|1.8|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-06-06-16|TLH-2016-06-28-14|1811652|PEARL LAKE @ SOUTHSIDE|G4HL062016-8|27-JUN-2016|11:35|11-JUL-2016|07:10|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|28-JUN-2016|13:30|SM 10200 H (mod.)|CLELL FORD|Precision data not available for at least one component due to small amount analyte in the QC sample. Refer to QA report for available precision data.