REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2016-10-24-07|TLH-2016-10-26-42|1844598|JOSHUA CR-1.2 MI N OF RT 760 A|G3SD102516-3|25-OCT-2016|10:30|07-NOV-2016|08:45|32211|Chlorophyll-a, Corrected|0.84|I|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844598|JOSHUA CR-1.2 MI N OF RT 760 A|G3SD102516-3|25-OCT-2016|10:30|07-NOV-2016|08:45|32210|Chlorophyll-a, Uncorrected|0.92|I|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844598|JOSHUA CR-1.2 MI N OF RT 760 A|G3SD102516-3|25-OCT-2016|10:30|07-NOV-2016|08:45|32219|Chlorophyll/Phaeophytin Ratio|1.6|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844598|JOSHUA CR-1.2 MI N OF RT 760 A|G3SD102516-3|25-OCT-2016|10:30|07-NOV-2016|08:45|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844599|HOG BAY @ CR 763|G3SD102516-4|25-OCT-2016|09:40|07-NOV-2016|08:45|32211|Chlorophyll-a, Corrected|4.7||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844599|HOG BAY @ CR 763|G3SD102516-4|25-OCT-2016|09:40|07-NOV-2016|08:45|32210|Chlorophyll-a, Uncorrected|7.3||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844599|HOG BAY @ CR 763|G3SD102516-4|25-OCT-2016|09:40|07-NOV-2016|08:45|32219|Chlorophyll/Phaeophytin Ratio|1.4|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844599|HOG BAY @ CR 763|G3SD102516-4|25-OCT-2016|09:40|07-NOV-2016|08:45|32218|Phaeophytin-a|4.0||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844600|SHELL CR. @ SR 31|G3SD102516-5|25-OCT-2016|08:45|07-NOV-2016|08:45|32211|Chlorophyll-a, Corrected|2.1||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844600|SHELL CR. @ SR 31|G3SD102516-5|25-OCT-2016|08:45|07-NOV-2016|08:45|32210|Chlorophyll-a, Uncorrected|4.0||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844600|SHELL CR. @ SR 31|G3SD102516-5|25-OCT-2016|08:45|07-NOV-2016|08:45|32219|Chlorophyll/Phaeophytin Ratio|1.3|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-10-24-07|TLH-2016-10-26-42|1844600|SHELL CR. @ SR 31|G3SD102516-5|25-OCT-2016|08:45|07-NOV-2016|08:45|32218|Phaeophytin-a|3.0||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-OCT-2016|13:45|SM 10200 H (mod.)|B.Paswater,C.Anderson, R.Murphy|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data.