REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2016-12-26-03|TLH-2016-12-29-05|1860435|ALLIGATOR CR SOUTH BRANCH @ SR768|G2SD25010009|28-DEC-2016|13:10|03-JAN-2017|13:55|32211|Chlorophyll-a, Corrected|0.90|I|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|29-DEC-2016|13:32|SM 10200 H (mod.)|COREY ANDERSON/ROSEMARY MURPHY|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-12-26-03|TLH-2016-12-29-05|1860435|ALLIGATOR CR SOUTH BRANCH @ SR768|G2SD25010009|28-DEC-2016|13:10|03-JAN-2017|13:55|32210|Chlorophyll-a, Uncorrected|0.89|I|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|29-DEC-2016|13:32|SM 10200 H (mod.)|COREY ANDERSON/ROSEMARY MURPHY|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-12-26-03|TLH-2016-12-29-05|1860435|ALLIGATOR CR SOUTH BRANCH @ SR768|G2SD25010009|28-DEC-2016|13:10|03-JAN-2017|13:55|32219|Chlorophyll/Phaeophytin Ratio|1.8|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|29-DEC-2016|13:32|SM 10200 H (mod.)|COREY ANDERSON/ROSEMARY MURPHY|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-12-26-03|TLH-2016-12-29-05|1860435|ALLIGATOR CR SOUTH BRANCH @ SR768|G2SD25010009|28-DEC-2016|13:10|03-JAN-2017|13:55|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|29-DEC-2016|13:32|SM 10200 H (mod.)|COREY ANDERSON/ROSEMARY MURPHY|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-12-26-03|TLH-2016-12-29-05|1860436|ALLIGATOR CR SOUTH BRANCH @ SR768 DUP|G2SD25010009-D|28-DEC-2016|13:15|03-JAN-2017|13:55|32211|Chlorophyll-a, Corrected|1.9||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|29-DEC-2016|13:32|SM 10200 H (mod.)|COREY ANDERSON/ROSEMARY MURPHY|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-12-26-03|TLH-2016-12-29-05|1860436|ALLIGATOR CR SOUTH BRANCH @ SR768 DUP|G2SD25010009-D|28-DEC-2016|13:15|03-JAN-2017|13:55|32210|Chlorophyll-a, Uncorrected|2.0||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|29-DEC-2016|13:32|SM 10200 H (mod.)|COREY ANDERSON/ROSEMARY MURPHY|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-12-26-03|TLH-2016-12-29-05|1860436|ALLIGATOR CR SOUTH BRANCH @ SR768 DUP|G2SD25010009-D|28-DEC-2016|13:15|03-JAN-2017|13:55|32219|Chlorophyll/Phaeophytin Ratio|1.7|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|29-DEC-2016|13:32|SM 10200 H (mod.)|COREY ANDERSON/ROSEMARY MURPHY|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2016-12-26-03|TLH-2016-12-29-05|1860436|ALLIGATOR CR SOUTH BRANCH @ SR768 DUP|G2SD25010009-D|28-DEC-2016|13:15|03-JAN-2017|13:55|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|29-DEC-2016|13:32|SM 10200 H (mod.)|COREY ANDERSON/ROSEMARY MURPHY|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data.