REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2017-02-27-14|TLH-2017-03-08-24|1878276|INDIAN KEY FILL AT SW END|G5SD030717-1|07-MAR-2017|12:45|15-MAR-2017|10:40|32211|Chlorophyll-a, Corrected|1.1|I|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Lab dup result is 1.5 for Chl:Ph Ratio, 0.93 I for Chl-a Corrected, 1.1 I for Chl-a Uncorrected, and 0.40 U for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2017-02-27-14|TLH-2017-03-08-24|1878276|INDIAN KEY FILL AT SW END|G5SD030717-1|07-MAR-2017|12:45|15-MAR-2017|10:40|32210|Chlorophyll-a, Uncorrected|1.3||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Lab dup result is 1.5 for Chl:Ph Ratio, 0.93 I for Chl-a Corrected, 1.1 I for Chl-a Uncorrected, and 0.40 U for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2017-02-27-14|TLH-2017-03-08-24|1878276|INDIAN KEY FILL AT SW END|G5SD030717-1|07-MAR-2017|12:45|15-MAR-2017|10:40|32219|Chlorophyll/Phaeophytin Ratio|1.6|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Lab dup result is 1.5 for Chl:Ph Ratio, 0.93 I for Chl-a Corrected, 1.1 I for Chl-a Uncorrected, and 0.40 U for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2017-02-27-14|TLH-2017-03-08-24|1878276|INDIAN KEY FILL AT SW END|G5SD030717-1|07-MAR-2017|12:45|15-MAR-2017|10:40|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Lab dup result is 1.5 for Chl:Ph Ratio, 0.93 I for Chl-a Corrected, 1.1 I for Chl-a Uncorrected, and 0.40 U for Phaeophytin-a. Precision data is unavailable due to the small amount of analyte in the QC sample. RQ-2017-02-27-14|TLH-2017-03-08-24|1878277|GRASSY KEY @ CURRY HAMMOCK CREEK|G5SD030717-4|07-MAR-2017|13:45|15-MAR-2017|10:40|32211|Chlorophyll-a, Corrected|0.68|I|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2017-02-27-14|TLH-2017-03-08-24|1878277|GRASSY KEY @ CURRY HAMMOCK CREEK|G5SD030717-4|07-MAR-2017|13:45|15-MAR-2017|10:40|32210|Chlorophyll-a, Uncorrected|0.68|I|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2017-02-27-14|TLH-2017-03-08-24|1878277|GRASSY KEY @ CURRY HAMMOCK CREEK|G5SD030717-4|07-MAR-2017|13:45|15-MAR-2017|10:40|32219|Chlorophyll/Phaeophytin Ratio|1.8|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2017-02-27-14|TLH-2017-03-08-24|1878277|GRASSY KEY @ CURRY HAMMOCK CREEK|G5SD030717-4|07-MAR-2017|13:45|15-MAR-2017|10:40|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2017-02-27-14|TLH-2017-03-08-24|1878278|6012C BY BRIDGE NO NAME KEY|G5SD030717-6|07-MAR-2017|14:50|15-MAR-2017|10:40|32211|Chlorophyll-a, Corrected|0.55|U|ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2017-02-27-14|TLH-2017-03-08-24|1878278|6012C BY BRIDGE NO NAME KEY|G5SD030717-6|07-MAR-2017|14:50|15-MAR-2017|10:40|32210|Chlorophyll-a, Uncorrected|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2017-02-27-14|TLH-2017-03-08-24|1878278|6012C BY BRIDGE NO NAME KEY|G5SD030717-6|07-MAR-2017|14:50|15-MAR-2017|10:40|32219|Chlorophyll/Phaeophytin Ratio|0.93|||0.0|0.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2017-02-27-14|TLH-2017-03-08-24|1878278|6012C BY BRIDGE NO NAME KEY|G5SD030717-6|07-MAR-2017|14:50|15-MAR-2017|10:40|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|08-MAR-2017|14:10|SM 10200 H (mod.)|C. ANDERSON/K.DEAETH|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data.