REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2018-04-02-73|TLH-2018-06-26-26|2003220|Pearl Lake @ Center|G4SD0137|25-JUN-2018|11:15|05-JUL-2018|08:30|32211|Chlorophyll-a, Corrected|2.4||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-JUN-2018|14:50|SM 10200 H (mod.)|J.FOSTER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2018-04-02-73|TLH-2018-06-26-26|2003220|Pearl Lake @ Center|G4SD0137|25-JUN-2018|11:15|05-JUL-2018|08:30|32210|Chlorophyll-a, Uncorrected|2.5||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-JUN-2018|14:50|SM 10200 H (mod.)|J.FOSTER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2018-04-02-73|TLH-2018-06-26-26|2003220|Pearl Lake @ Center|G4SD0137|25-JUN-2018|11:15|05-JUL-2018|08:30|32218|Phaeophytin-a|0.40|U|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-JUN-2018|14:50|SM 10200 H (mod.)|J.FOSTER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2018-04-02-73|TLH-2018-06-26-26|2003221|Lake Henry @ Middle|G4SD0167|25-JUN-2018|10:10|05-JUL-2018|08:30|32211|Chlorophyll-a, Corrected|9.2||ug/L|0.55|1.7|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-JUN-2018|14:50|SM 10200 H (mod.)|J.FOSTER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2018-04-02-73|TLH-2018-06-26-26|2003221|Lake Henry @ Middle|G4SD0167|25-JUN-2018|10:10|05-JUL-2018|08:30|32210|Chlorophyll-a, Uncorrected|9.9||ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-JUN-2018|14:50|SM 10200 H (mod.)|J.FOSTER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2018-04-02-73|TLH-2018-06-26-26|2003221|Lake Henry @ Middle|G4SD0167|25-JUN-2018|10:10|05-JUL-2018|08:30|32218|Phaeophytin-a|0.47|I|ug/L|0.40|1.2|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|26-JUN-2018|14:50|SM 10200 H (mod.)|J.FOSTER|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2018-04-02-73|TLH-2018-06-26-48|2003278|Pearl Lake @ Center|G4SD0137|25-JUN-2018|11:15|27-JUN-2018|11:30|31648|Escherichia Coli-Quanti-Tray|1.0|Q|MPN/100 mL|1.0|1.0|MICRO-QT|Enterococci by Enterolert QuantiTray|26-JUN-2018|14:25|SM 9223 Quanti-Tray|J.FOSTER| RQ-2018-04-02-73|TLH-2018-06-26-48|2003279|Lake Henry @ Middle|G4SD0167|25-JUN-2018|10:10|27-JUN-2018|11:30|31648|Escherichia Coli-Quanti-Tray|9.6|Q|MPN/100 mL|1.0|1.0|MICRO-QT|Enterococci by Enterolert QuantiTray|26-JUN-2018|14:25|SM 9223 Quanti-Tray|J.FOSTER|