REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2018-11-12-60|TLH-2018-11-21-45|2043497|Powell Creek|G3SD0144|20-NOV-2018|09:40|30-NOV-2018|09:57||Total Alkalinity|223||mg CaCO3/L|0.65|2.5|||||SM 2320 B-97|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043497|Powell Creek|G3SD0144|20-NOV-2018|09:40|21-NOV-2018|15:37|76|Turbidity|3.9||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043497|Powell Creek|G3SD0144|20-NOV-2018|09:40|03-DEC-2018|20:21|940|Chloride|40||mg Cl/L|0.40|1.2|||||EPA 300.0 Rev. 2.1|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043497|Powell Creek|G3SD0144|20-NOV-2018|09:40|21-NOV-2018|16:14|80|Color (true)|60||PCU|2.5|6.0|||||SM 2120 B|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043497|Powell Creek|G3SD0144|20-NOV-2018|09:40|30-NOV-2018|09:57|951|Fluoride|0.17||mg F/L|0.035|0.10|||||SM 4500 F-C-97|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043497|Powell Creek|G3SD0144|20-NOV-2018|09:40|03-DEC-2018|20:21|945|Sulfate|6.4||mg SO4/L|0.40|1.2|||||EPA 300.0 Rev. 2.1|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043497|Powell Creek|G3SD0144|20-NOV-2018|09:40|26-NOV-2018|16:02|70300|TDS|326||mg/L|15|25|||||SM 2540 C-97|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043497|Powell Creek|G3SD0144|20-NOV-2018|09:40|26-NOV-2018|16:02|530|TSS|7|I|mg/L|2.0|10|||||SM 2540 D-97|Steve Cofone|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-45|2043498|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|11:10|610|Ammonia-N|0.13||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043498|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|12:23|630|NO2NO3-N|0.020||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043498|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|08:54|665|Total-P|0.24||mg P/L|0.0050|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|28-NOV-2018|12:35|EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043498|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|09:57|625|Kjeldahl Nitrogen|0.87||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|28-NOV-2018|11:50|EPA 351.2 Rev. 2.0|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043498|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|03:14|680|Organic Carbon|13||mg C/L|0.50|1.0|||||SM 5310 B-00|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-45|2043499|Powell Creek|G3SD0144|20-NOV-2018|09:40|21-NOV-2018|16:17|671|O-Phosphate-P|0.12||mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|28-NOV-2018|16:36|1007|Barium|18.8||ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium, and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|28-NOV-2018|16:36|916|Calcium|89.4||mg/L|0.075|0.30|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium, and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|28-NOV-2018|16:36|1045|Iron|1.17E+03||ug/L|30|120|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium, and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|28-NOV-2018|16:36|927|Magnesium|5.73||mg/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium, and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|28-NOV-2018|16:36|937|Potassium|2.1||mg/L|0.30|1.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium, and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|28-NOV-2018|16:36|929|Sodium|22.8||mg/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium, and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|28-NOV-2018|16:36|1092|Zinc|5.0|U|ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium, and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1105|Aluminum|56||ug/L|3.0|12|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1097|Antimony|0.19|I|ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1002|Arsenic|1.85||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1022|Boron|53.3||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1027|Cadmium|0.020|U|ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1034|Chromium|0.79|I|ug/L|0.40|1.6|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1042|Copper|0.20|U|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1051|Lead|0.13|I|ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1067|Nickel|0.58|I|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1147|Selenium|0.20|U|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1077|Silver|0.010|U|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2018-11-12-60|TLH-2018-11-21-49|2043503|Powell Creek|G3SD0144|20-NOV-2018|09:40|29-NOV-2018|18:50|1059|Thallium|0.10|U|ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|26-NOV-2018|17:30|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable for one of two spiked samples because of high analyte concentration in the QC sample.