REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2019-03-04-70|TLH-2019-03-14-44|2069776|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|20-MAR-2019|07:53||Total Alkalinity|85||mg CaCO3/L|0.65|2.5|||||SM 2320 B-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069776|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|14-MAR-2019|17:11|76|Turbidity|4.9||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069776|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|17-MAR-2019|01:31|71870|Bromide|13||mg Br/L|0.52|1.6|||||EPA 300.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069776|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|20-MAR-2019|05:12|951|Fluoride|0.46||mg F/L|0.070|0.20|||||SM 4500 F-C-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069776|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|15-MAR-2019|17:15|530|TSS|8|IA|mg/L|3.0|10|||||SM 2540 D-97|Steve Cofone|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-44|2069777|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|19-MAR-2019|09:31|610|Ammonia-N|0.070||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069777|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|18-MAR-2019|13:16|630|NO2NO3-N|0.005|I|mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069777|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|20-MAR-2019|11:24|665|Total-P|0.16||mg P/L|0.010|0.10|365.1 (MARCH 1983)|Automated, ascorbic acid|19-MAR-2019|13:40|EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069777|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|20-MAR-2019|15:35|625|Kjeldahl Nitrogen|0.85||mg N/L|0.16|0.40|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|19-MAR-2019|12:20|EPA 351.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069777|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|21-MAR-2019|01:56|680|Organic Carbon|14||mg C/L|0.50|1.0|||||SM 5310 B-00|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069778|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|14-MAR-2019|16:52|671|O-Phosphate-P|0.11||mg P/L|0.040|0.10|||||EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069779|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|20-MAR-2019|07:27||Total Alkalinity|91|A|mg CaCO3/L|0.65|2.5|||||SM 2320 B-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069779|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|14-MAR-2019|17:11|76|Turbidity|3.5||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069779|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|17-MAR-2019|01:48|71870|Bromide|19||mg Br/L|0.65|2.0|||||EPA 300.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069779|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|20-MAR-2019|04:56|951|Fluoride|0.54||mg F/L|0.070|0.20|||||SM 4500 F-C-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069779|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|18-MAR-2019|14:58|530|TSS|5|I|mg/L|3.0|10|||||SM 2540 D-97|Steve Cofone|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-44|2069780|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|19-MAR-2019|09:38|610|Ammonia-N|0.008||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069780|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|18-MAR-2019|13:22|630|NO2NO3-N|0.004|U|mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069780|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|20-MAR-2019|11:25|665|Total-P|0.15||mg P/L|0.010|0.10|365.1 (MARCH 1983)|Automated, ascorbic acid|19-MAR-2019|13:40|EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069780|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|20-MAR-2019|15:37|625|Kjeldahl Nitrogen|0.77||mg N/L|0.16|0.40|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|19-MAR-2019|12:20|EPA 351.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069780|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|21-MAR-2019|09:03|680|Organic Carbon|13||mg C/L|1.0|2.0|||||SM 5310 B-00|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069781|Apollo Waterway @ Bend|G3SD0069|13-MAR-2019|11:10|14-MAR-2019|15:28|671|O-Phosphate-P|0.10||mg P/L|0.040|0.10|||||EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069782|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|20-MAR-2019|11:04||Total Alkalinity|131||mg CaCO3/L|0.65|2.5|||||SM 2320 B-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069782|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|14-MAR-2019|17:11|76|Turbidity|2.4||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069782|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|17-MAR-2019|02:05|71870|Bromide|31||mg Br/L|1.3|4.0|||||EPA 300.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069782|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|20-MAR-2019|06:43|951|Fluoride|0.80||mg F/L|0.18|0.50|||||SM 4500 F-C-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069782|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|18-MAR-2019|14:58|530|TSS|4|I|mg/L|3.0|10|||||SM 2540 D-97|Steve Cofone|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-44|2069783|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|20-MAR-2019|11:16||Total Alkalinity|132||mg CaCO3/L|0.65|2.5|||||SM 2320 B-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069783|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|14-MAR-2019|17:11|76|Turbidity|2.9||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069783|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|17-MAR-2019|02:22|71870|Bromide|30||mg Br/L|1.3|4.0|||||EPA 300.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069783|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|20-MAR-2019|06:47|951|Fluoride|0.79||mg F/L|0.18|0.50|||||SM 4500 F-C-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069783|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|18-MAR-2019|14:58|530|TSS|4|I|mg/L|3.0|10|||||SM 2540 D-97|Steve Cofone|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-44|2069784|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|19-MAR-2019|09:40|610|Ammonia-N|0.006||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069784|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|18-MAR-2019|13:23|630|NO2NO3-N|0.004|U|mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069784|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|20-MAR-2019|11:26|665|Total-P|0.17||mg P/L|0.010|0.10|365.1 (MARCH 1983)|Automated, ascorbic acid|19-MAR-2019|13:40|EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069784|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|20-MAR-2019|15:38|625|Kjeldahl Nitrogen|0.75||mg N/L|0.16|0.40|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|19-MAR-2019|12:20|EPA 351.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069784|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|22-MAR-2019|07:16|680|Organic Carbon|9.7||mg C/L|1.0|2.0|||||SM 5310 B-00|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069785|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|19-MAR-2019|09:41|610|Ammonia-N|0.007||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069785|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|18-MAR-2019|13:24|630|NO2NO3-N|0.004|U|mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069785|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|20-MAR-2019|11:30|665|Total-P|0.18||mg P/L|0.010|0.10|365.1 (MARCH 1983)|Automated, ascorbic acid|19-MAR-2019|13:40|EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069785|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|20-MAR-2019|15:40|625|Kjeldahl Nitrogen|0.67||mg N/L|0.16|0.40|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|19-MAR-2019|12:20|EPA 351.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069785|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|22-MAR-2019|07:31|680|Organic Carbon|9.4||mg C/L|1.0|2.0|||||SM 5310 B-00|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069786|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|14-MAR-2019|16:53|671|O-Phosphate-P|0.12||mg P/L|0.040|0.10|||||EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069787|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|14-MAR-2019|16:54|671|O-Phosphate-P|0.12||mg P/L|0.040|0.10|||||EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069788|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|21-MAR-2019|20:41||Total Alkalinity|236||mg CaCO3/L|0.65|2.5|||||SM 2320 B-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069788|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|14-MAR-2019|17:11|76|Turbidity|20|A|NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069788|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|21-MAR-2019|18:41|940|Chloride|63||mg Cl/L|0.40|1.2|||||EPA 300.0 Rev. 2.1|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069788|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|14-MAR-2019|18:01|80|Color (true)|35|A|PCU|2.5|6.0|||||SM 2120 B|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069788|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|21-MAR-2019|20:41|951|Fluoride|0.39||mg F/L|0.035|0.10|||||SM 4500 F-C-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069788|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|21-MAR-2019|18:41|945|Sulfate|110||mg SO4/L|0.40|1.2|||||EPA 300.0 Rev. 2.1|Steve Cofone|Sulfate: Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-44|2069788|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|15-MAR-2019|17:15|70300|TDS|564|A|mg/L|15|25|||||SM 2540 C-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069788|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|15-MAR-2019|17:15|530|TSS|11|A|mg/L|2.0|10|||||SM 2540 D-97|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069789|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|19-MAR-2019|13:04|610|Ammonia-N|0.33||mg N/L|0.020|0.050|||||EPA 350.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069789|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|19-MAR-2019|15:12|630|NO2NO3-N|1.0||mg N/L|0.040|0.10|||||EPA 353.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069789|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|19-MAR-2019|10:10|665|Total-P|0.14||mg P/L|0.0050|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|18-MAR-2019|14:30|EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069789|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|20-MAR-2019|10:20|625|Kjeldahl Nitrogen|1.4||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|19-MAR-2019|12:20|EPA 351.2 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069789|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|21-MAR-2019|02:10|680|Organic Carbon|16||mg C/L|0.50|1.0|||||SM 5310 B-00|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-44|2069790|Phillippi Creek@Proctor|G3SD0091|13-MAR-2019|13:10|14-MAR-2019|16:42|671|O-Phosphate-P|0.017||mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|18-MAR-2019|14:48||AMPA|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|18-MAR-2019|08:00|EPA 8321B|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|18-MAR-2019|18:51||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|18-MAR-2019|08:00|EPA 8321B|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|18-MAR-2019|18:51||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|18-MAR-2019|08:00|EPA 8321B|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|18-MAR-2019|14:48||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|18-MAR-2019|08:00|EPA 8321B|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|18-MAR-2019|14:48||Glyphosate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|18-MAR-2019|08:00|EPA 8321B|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|18-MAR-2019|18:51||Sucralose|0.010|U|ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|18-MAR-2019|08:00|EPA 8321B|Steve Cofone| RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21|39730|2,4-D|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Bentazon|0.0024|I|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Diuron|0.0028|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Fluridone|0.0048||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Imazapyr|0.025||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Imidacloprid|0.027|J|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-50|2069849|MyakkaRiver(Tidal)@US41|G3SD0068|13-MAR-2019|10:20|26-MAR-2019|01:21||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|19-MAR-2019|10:00|EPA 8321B|Steve Cofone|Refer to the narrative for an explanation of QC Codes. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|21-MAR-2019|16:58|1007|Barium|15||ug/L|3.0|12|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|21-MAR-2019|16:58|916|Calcium|119||mg/L|0.22|0.90|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|21-MAR-2019|16:58|1045|Iron|350|I|ug/L|90|360|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|21-MAR-2019|16:58|927|Magnesium|239||mg/L|0.12|0.48|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|21-MAR-2019|17:04|937|Potassium|73||mg/L|6.0|24|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|21-MAR-2019|17:04|929|Sodium|1.92E+03||mg/L|10|40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|21-MAR-2019|16:58|1092|Zinc|15|U|ug/L|15|60|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|07:25|1105|Aluminum|160|I|ug/L|50|200|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|04:49|1097|Antimony|0.20|U|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|04:49|1002|Arsenic|1.48||ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|07:25|1022|Boron|873||ug/L|20|80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|04:49|1027|Cadmium|0.080|U|ug/L|0.080|0.32|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|30-MAR-2019|10:18|1034|Chromium|4.0|U|ug/L|4.0|16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|04:49|1042|Copper|1.6|U|ug/L|1.6|3.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|07:25|1051|Lead|2.0|U|ug/L|2.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|04:49|1067|Nickel|2.0|U|ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|04:49|1147|Selenium|0.80|U|ug/L|0.80|3.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|28-MAR-2019|04:49|1077|Silver|0.040|U|ug/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069850|Rock Creek@EisenhowerDr|G3SD0070|13-MAR-2019|10:45|04-APR-2019|13:03|1059|Thallium|1.0|U|ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|21-MAR-2019|17:10|1007|Barium|17||ug/L|3.0|12|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|21-MAR-2019|17:10|916|Calcium|208||mg/L|0.22|0.90|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|21-MAR-2019|17:10|1045|Iron|140|I|ug/L|90|360|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|21-MAR-2019|17:17|927|Magnesium|552||mg/L|0.80|3.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|21-MAR-2019|17:17|937|Potassium|169||mg/L|6.0|24|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|22-MAR-2019|15:01|929|Sodium|4.51E+03||mg/L|25|100|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|21-MAR-2019|17:10|1092|Zinc|15|U|ug/L|15|60|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|07:35|1105|Aluminum|98|I|ug/L|50|200|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|04:59|1097|Antimony|0.29|I|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|04:59|1002|Arsenic|2.23||ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|07:35|1022|Boron|2.06E+03||ug/L|20|80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|04:59|1027|Cadmium|0.080|U|ug/L|0.080|0.32|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|30-MAR-2019|10:25|1034|Chromium|4.0|U|ug/L|4.0|16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|04:59|1042|Copper|1.6|U|ug/L|1.6|3.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|07:35|1051|Lead|2.0|U|ug/L|2.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|04:59|1067|Nickel|2.0|U|ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|04:59|1147|Selenium|0.80|U|ug/L|0.80|3.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|28-MAR-2019|04:59|1077|Silver|0.040|U|ug/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069851|Little Alligator@Midway|G3SD0071|13-MAR-2019|11:45|30-MAR-2019|10:25|1059|Thallium|1.0|U|ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|21-MAR-2019|17:23|1007|Barium|16||ug/L|3.0|12|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|21-MAR-2019|17:23|916|Calcium|203||mg/L|0.22|0.90|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|21-MAR-2019|17:23|1045|Iron|220|I|ug/L|90|360|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|21-MAR-2019|17:29|927|Magnesium|539||mg/L|0.80|3.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|21-MAR-2019|17:29|937|Potassium|165||mg/L|6.0|24|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|22-MAR-2019|15:07|929|Sodium|4.38E+03||mg/L|25|100|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|21-MAR-2019|17:23|1092|Zinc|15|U|ug/L|15|60|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.7 Rev. 4.4|Steve Cofone|Batch matrix spike recoveries for calcium, magnesium, potassium and sodium are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|07:45|1105|Aluminum|150|I|ug/L|50|200|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|05:08|1097|Antimony|0.26|I|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|05:08|1002|Arsenic|2.23||ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|07:45|1022|Boron|2.02E+03||ug/L|20|80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|05:08|1027|Cadmium|0.080|U|ug/L|0.080|0.32|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|30-MAR-2019|10:32|1034|Chromium|4.0|U|ug/L|4.0|16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|05:08|1042|Copper|1.6|U|ug/L|1.6|3.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|07:45|1051|Lead|2.0|U|ug/L|2.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|05:08|1067|Nickel|2.0|U|ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|05:08|1147|Selenium|0.80|U|ug/L|0.80|3.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|28-MAR-2019|05:08|1077|Silver|0.040|U|ug/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample. RQ-2019-03-04-70|TLH-2019-03-14-51|2069852|Little Alligator@Midway|G3SD0071_DUP|13-MAR-2019|11:50|30-MAR-2019|10:32|1059|Thallium|1.0|U|ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|20-MAR-2019|16:35|EPA 200.8 Rev. 5.4|Steve Cofone|Batch matrix spike recoveries for boron are unavailable because of high analyte concentration in the QC sample.