REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2019-07-29-74|TLH-2019-10-15-01|2127770|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|19-OCT-2019|07:43||Total Alkalinity|15||mg CaCO3/L|0.65|2.5|||||SM 2320 B-97|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127770|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|15-OCT-2019|16:32|76|Turbidity|6.0|A|NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127770|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|15:57|940|Chloride|36||mg Cl/L|0.20|0.60|||||EPA 300.0 Rev. 2.1|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127770|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|15-OCT-2019|17:43|80|Color (true)|100||PCU|2.5|6.0|||||SM 2120 B|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127770|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|19-OCT-2019|07:43|951|Fluoride|0.046|I|mg F/L|0.035|0.10|||||SM 4500 F-C-97|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127770|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|15:57|945|Sulfate|29||mg SO4/L|0.20|0.60|||||EPA 300.0 Rev. 2.1|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127770|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|16-OCT-2019|13:25|70300|TDS|164||mg/L|15|25|||||SM 2540 C-97|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127770|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|16-OCT-2019|13:25|530|TSS|5|I|mg/L|2.0|10|||||SM 2540 D-97|N.Reistad, G.Snorek, C.Conley|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2019-07-29-74|TLH-2019-10-15-01|2127771|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|14:50|610|Ammonia-N|0.21||mg N/L|0.020|0.050|||||EPA 350.1 Rev. 2.0|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127771|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|11:12|630|NO2NO3-N|0.074||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127771|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|16:49|665|Total-P|0.042||mg P/L|0.0020|0.0050|365.1 (MARCH 1983)|Automated, ascorbic acid|16-OCT-2019|10:45|EPA 365.1 Rev. 2.0|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127771|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|20:28|625|Kjeldahl Nitrogen|1.3||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|16-OCT-2019|12:17|EPA 351.2 Rev. 2.0|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127771|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:07|680|Organic Carbon|20||mg C/L|0.50|1.0|||||SM 5310 B-00|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-01|2127772|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|15-OCT-2019|15:51|671|O-Phosphate-P|0.007|I|mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|15-OCT-2019|15:52|99937|Sucralose|0.010|UJ|ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|15-OCT-2019|14:45|EPA 8321B|N.Reistad, G.Snorek, C.Conley|Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. Surrogate spike recovery exceeding the control limits in sample and sample duplicate matrix spikes. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|15-OCT-2019|21:29||AMPA|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|15-OCT-2019|14:45|EPA 8321B|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|16-OCT-2019|10:59||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|15-OCT-2019|14:45|EPA 8321B|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|16-OCT-2019|10:59||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|15-OCT-2019|14:45|EPA 8321B|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|15-OCT-2019|21:29||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|15-OCT-2019|14:45|EPA 8321B|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|15-OCT-2019|21:29||Glyphosate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|15-OCT-2019|14:45|EPA 8321B|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28|39730|2,4-D|0.010||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Acetaminophen|0.010|I|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Afidopyropen|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Bentazon|0.0063||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Benzovindiflupyr|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Imazapyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Imidacloprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Mandestrobin|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-12|2127774|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|18-OCT-2019|02:28||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-OCT-2019|10:00|EPA 8321B|N.Reistad, G.Snorek, C.Conley|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|14:46|1007|Barium|30.4||ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.7 Rev. 4.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|14:46|916|Calcium|13.0||mg/L|0.075|0.30|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.7 Rev. 4.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|14:46|1045|Iron|1.01E+03||ug/L|30|120|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.7 Rev. 4.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|14:46|927|Magnesium|4.43||mg/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.7 Rev. 4.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|14:46|937|Potassium|6.1||mg/L|0.30|1.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.7 Rev. 4.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|14:46|929|Sodium|22.1||mg/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.7 Rev. 4.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|17-OCT-2019|14:46|1092|Zinc|5.0|U|ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.7 Rev. 4.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1105|Aluminum|367||ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1097|Antimony|0.056|I|ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1002|Arsenic|0.63||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1022|Boron|92.9||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1027|Cadmium|0.020|U|ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|31-OCT-2019|04:31|1034|Chromium|1.1|I|ug/L|0.40|1.6|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|24-OCT-2019|21:01|1042|Copper|0.55|I|ug/L|0.40|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1051|Lead|0.24|I|ug/L|0.20|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|31-OCT-2019|07:24|1067|Nickel|0.50|U|ug/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|28-OCT-2019|17:00|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1147|Selenium|0.22|I|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1077|Silver|0.010|U|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-14|2127776|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|23-OCT-2019|04:27|1059|Thallium|0.10|U|ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-OCT-2019|16:55|EPA 200.8 Rev. 5.4|N.Reistad, G.Snorek, C.Conley| RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Acetochlor|0.24|U|ng/L|0.24|0.98|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Alachlor|0.24|U|ng/L|0.24|0.98|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|82184|Ametryn|0.59|U|ng/L|0.59|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|39033|Atrazine|0.51|I|ng/L|0.24|0.98|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Atrazine Desethyl|1.5|U|ng/L|1.5|5.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Azinphos Methyl|4.9|U|ng/L|4.9|20|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Bromacil|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Butylate|0.39|U|ng/L|0.39|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|38932|Chlorpyrifos Ethyl|0.24|U|ng/L|0.24|0.98|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|38740|Chlorpyrifos Methyl|0.098|U|ng/L|0.098|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Cyanazine|3.2|U|ng/L|3.2|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Demeton|6.8|UJ|ng/L|6.8|27|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Diazinon|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Dimethenamid|0.098|U|ng/L|0.098|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|81888|Disulfoton|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Dithiopyr|0.098|U|ng/L|0.098|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||EPTC|1.2|U|ng/L|1.2|4.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|39398|Ethion|0.15|U|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|81758|Ethoprop|0.098|U|ng/L|0.098|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Fenamiphos|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Fipronil|0.24|U|ng/L|0.24|0.98|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Fipronil Desulfinyl|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Fipronil Sulfide|0.15|UJ|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Fipronil Sulfone|0.15|U|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Fonofos|0.20|U|ng/L|0.20|0.78|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|38815|Hexazinone|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|39530|Malathion|0.34|U|ng/L|0.34|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Metalaxyl|0.29|U|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Metolachlor|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|81408|Metribuzin|0.73|UJ|ng/L|0.73|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|39610|Mevinphos|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Molinate|0.29|U|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|78064|Norflurazon|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Oxadiazon|0.10|I|ng/L|0.098|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Parathion Ethyl|0.24|U|ng/L|0.24|0.98|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Parathion Methyl|0.54|U|ng/L|0.54|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Pendimethalin|0.98|U|ng/L|0.98|3.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|46313|Phorate|0.24|U|ng/L|0.24|0.98|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Prodiamine|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|39056|Prometon|0.88|U|ng/L|0.88|3.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|39057|Prometryn|0.20|U|ng/L|0.20|0.78|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|39055|Simazine|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Tebuconazole|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57|82088|Terbufos|0.098|U|ng/L|0.098|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2019-07-29-74|TLH-2019-10-15-15|2127777|Arbuckle Branch|G4SD0172|14-OCT-2019|11:10|22-OCT-2019|23:57||Terbuthylazine|0.42|U|ng/L|0.42|1.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|18-OCT-2019|09:00|EPA 8270E|N.Reistad, G.Snorek, C.Conley|MS accuracy for bromacil, metolachlor, fipronil sulfone, atrazine, metalaxyl, and metribuzin not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes.