REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2019-08-26-15|TLH-2019-09-04-27|2116405|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|06-SEP-2019|03:07||Total Alkalinity|175||mg CaCO3/L|0.65|2.5|||||SM 2320 B-97|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116405|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|04-SEP-2019|16:44|76|Turbidity|6.9|A|NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116405|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|06-SEP-2019|23:26|940|Chloride|59||mg Cl/L|0.40|1.2|||||EPA 300.0 Rev. 2.1|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116405|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|04-SEP-2019|17:42|80|Color (true)|59||PCU|2.5|6.0|||||SM 2120 B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116405|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|06-SEP-2019|03:07|951|Fluoride|0.34||mg F/L|0.035|0.10|||||SM 4500 F-C-97|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116405|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|06-SEP-2019|23:26|945|Sulfate|94||mg SO4/L|0.40|1.2|||||EPA 300.0 Rev. 2.1|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116405|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|09-SEP-2019|15:08|70300|TDS|445||mg/L|15|25|||||SM 2540 C-97|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116405|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|09-SEP-2019|15:08|530|TSS|4|I|mg/L|2.0|10|||||SM 2540 D-97|Kirby Wolfe|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2019-08-26-15|TLH-2019-09-04-27|2116406|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|10-SEP-2019|12:04|610|Ammonia-N|0.079||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116406|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|06-SEP-2019|09:55|630|NO2NO3-N|0.54||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116406|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|11-SEP-2019|11:11|665|Total-P|0.11||mg P/L|0.0050|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|10-SEP-2019|09:48|EPA 365.1 Rev. 2.0|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116406|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|06-SEP-2019|15:21|625|Kjeldahl Nitrogen|1.0||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|05-SEP-2019|12:00|EPA 351.2 Rev. 2.0|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116406|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|06-SEP-2019|05:29|680|Organic Carbon|16||mg C/L|0.50|1.0|||||SM 5310 B-00|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-27|2116407|PhillippeCreek@Proctor|G3SD0091|03-SEP-2019|10:15|04-SEP-2019|15:39|671|O-Phosphate-P|0.023||mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|18-SEP-2019|10:54|99937|Sucralose|0.25||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe|Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|09-SEP-2019|13:02||AMPA|0.24|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|15:22||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|15:22||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|09-SEP-2019|13:02||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|09-SEP-2019|13:02||Glyphosate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08|39730|2,4-D|0.021||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Afidopyropen|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Bentazon|0.015||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Benzovindiflupyr|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Carbamazepine|0.0012|I|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Clothianidin|0.015||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Fluridone|0.010||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Imazapyr|0.22||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Imidacloprid|0.62||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||MCPP|0.0096|J|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Mandestrobin|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Naproxen|0.015|I|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Primidone|0.0061|I|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Thiamethoxam|0.052||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116415|NorthCreek@OaksCreekCt|G3SD0064|03-SEP-2019|11:00|06-SEP-2019|12:08||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|18-SEP-2019|11:05|99937|Sucralose|0.28||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe|Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|09-SEP-2019|13:12||AMPA|0.33|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|15:35||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|15:35||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|09-SEP-2019|13:12||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|09-SEP-2019|13:12||Glyphosate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43|39730|2,4-D|0.20||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Afidopyropen|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Bentazon|0.031||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Benzovindiflupyr|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Carbamazepine|0.0017|I|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Clothianidin|0.012||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Diuron|0.078||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Fluridone|0.076||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Imazapyr|0.39||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Imidacloprid|0.38||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||MCPP|0.0036|IJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Mandestrobin|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Primidone|0.0060|I|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Thiamethoxam|0.014||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116416|NorthCreek(Tidal)@41|G3SD0089|03-SEP-2019|11:20|06-SEP-2019|12:43||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|18-SEP-2019|11:17|99937|Sucralose|0.31||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe|Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|13:23||AMPA|0.30|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|06-SEP-2019|15:49||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|06-SEP-2019|15:49||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|13:23||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|13:23||Glyphosate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|06-SEP-2019|10:30|EPA 8321B|Kirby Wolfe| RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49|39730|2,4-D|0.13||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Afidopyropen|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Bentazon|0.035||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Benzovindiflupyr|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Carbamazepine|0.0014|I|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Clothianidin|0.012||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Diuron|0.054||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|15:38||Fluridone|0.32||ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Imazapyr|0.55||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Imidacloprid|0.34||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||MCPP|0.0034|IJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Mandestrobin|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Primidone|0.0069|I|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Thiamethoxam|0.013||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Tolfenpyrad|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction. RQ-2019-08-26-15|TLH-2019-09-04-31|2116417|NorthCreek(Tidal)@41|G3SD0089_DUP|03-SEP-2019|11:25|09-SEP-2019|20:49||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|05-SEP-2019|09:00|EPA 8321B|Kirby Wolfe|J - second source check standards for some analytes were not available for analysis. MS accuracy for 2,4-D and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. Refer to the narrative for an explanation of QC Codes. Results confirmed in re-extraction.