REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2019-09-23-47|TLH-2019-10-24-40|2131140|ENRE 10 off Chokoloskee|G1SD0075|23-OCT-2019|11:30|04-NOV-2019|10:46|32211|Chlorophyll-a, Corrected|12||ug/L|1.6|5.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131140|ENRE 10 off Chokoloskee|G1SD0075|23-OCT-2019|11:30|04-NOV-2019|10:46|32210|Chlorophyll-a, Uncorrected|14||ug/L|1.2|3.6|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131140|ENRE 10 off Chokoloskee|G1SD0075|23-OCT-2019|11:30|04-NOV-2019|10:46|32218|Phaeophytin-a|1.8|U|ug/L|1.8|5.4|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131141|ENRE10 Lopez River|G5SD0092|23-OCT-2019|11:45|04-NOV-2019|10:46|32211|Chlorophyll-a, Corrected|5.0||ug/L|1.4|4.1|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131141|ENRE10 Lopez River|G5SD0092|23-OCT-2019|11:45|04-NOV-2019|10:46|32210|Chlorophyll-a, Uncorrected|5.8||ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131141|ENRE10 Lopez River|G5SD0092|23-OCT-2019|11:45|04-NOV-2019|10:46|32218|Phaeophytin-a|1.5|U|ug/L|1.5|4.5|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131142|ENRE9 Lopez River|G5SD0093|23-OCT-2019|12:00|04-NOV-2019|10:46|32211|Chlorophyll-a, Corrected|5.3||ug/L|1.6|4.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131142|ENRE9 Lopez River|G5SD0093|23-OCT-2019|12:00|04-NOV-2019|10:46|32210|Chlorophyll-a, Uncorrected|6.6||ug/L|1.2|3.5|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131142|ENRE9 Lopez River|G5SD0093|23-OCT-2019|12:00|04-NOV-2019|10:46|32218|Phaeophytin-a|1.8|U|ug/L|1.8|5.3|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131143|ENRE11 Sunday Bay|G5SD0094|23-OCT-2019|12:15|04-NOV-2019|10:46|32211|Chlorophyll-a, Corrected|11||ug/L|1.4|4.1|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131143|ENRE11 Sunday Bay|G5SD0094|23-OCT-2019|12:15|04-NOV-2019|10:46|32210|Chlorophyll-a, Uncorrected|13||ug/L|1.0|3.0|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131143|ENRE11 Sunday Bay|G5SD0094|23-OCT-2019|12:15|04-NOV-2019|10:46|32218|Phaeophytin-a|2.8|I|ug/L|1.5|4.5|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131144|ENRE 11 at Huston Bay|G5SD0026|23-OCT-2019|12:40|04-NOV-2019|10:46|32211|Chlorophyll-a, Corrected|19||ug/L|1.6|4.8|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131144|ENRE 11 at Huston Bay|G5SD0026|23-OCT-2019|12:40|04-NOV-2019|10:46|32210|Chlorophyll-a, Uncorrected|20||ug/L|1.2|3.5|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-40|2131144|ENRE 11 at Huston Bay|G5SD0026|23-OCT-2019|12:40|04-NOV-2019|10:46|32218|Phaeophytin-a|1.8|U|ug/L|1.8|5.3|SOP-BB29|Phytoplankton Sample Filtering for Chlorophyll a Analysis by Spectrophotometry|24-OCT-2019|14:30|SM 10200 H (mod.)|N.Reistad / G.Snorek|Precision data is not available for at least one component due to the small amount of analyte in the QC sample. Refer to QA report for available precision data. RQ-2019-09-23-47|TLH-2019-10-24-41|2131145|ENRE10 Lopez River|G5SD0092|23-OCT-2019|11:45|24-OCT-2019|16:20|31649|ENTEROCOCCI-ENTEROLERT|10|U|MPN/100 mL|10|10|MICRO-MF|Microbiological Preparation for Membrane Filter Analysis|23-OCT-2019|16:20|Enterolert/QT|N.Reistad / G.Snorek| RQ-2019-09-23-47|TLH-2019-10-24-41|2131145|ENRE10 Lopez River|G5SD0092|23-OCT-2019|11:45|24-OCT-2019|15:28|31616|Fecal Coliforms-Membrane Filter|10|U|cfu/100 mL|10|10|MICRO-MF|Microbiological Preparation for Membrane Filter Analysis|23-OCT-2019|16:22|SM 9222 D|N.Reistad / G.Snorek| RQ-2019-09-23-47|TLH-2019-10-24-41|2131146|ENRE9 Lopez River|G5SD0093|23-OCT-2019|12:00|24-OCT-2019|16:20|31649|ENTEROCOCCI-ENTEROLERT|10|U|MPN/100 mL|10|10|MICRO-MF|Microbiological Preparation for Membrane Filter Analysis|23-OCT-2019|16:20|Enterolert/QT|N.Reistad / G.Snorek| RQ-2019-09-23-47|TLH-2019-10-24-41|2131146|ENRE9 Lopez River|G5SD0093|23-OCT-2019|12:00|24-OCT-2019|15:28|31616|Fecal Coliforms-Membrane Filter|20|B|cfu/100 mL|10|10|MICRO-MF|Microbiological Preparation for Membrane Filter Analysis|23-OCT-2019|16:22|SM 9222 D|N.Reistad / G.Snorek| RQ-2019-09-23-47|TLH-2019-10-24-41|2131147|ENRE11 Sunday Bay|G5SD0094|23-OCT-2019|12:15|24-OCT-2019|16:20|31649|ENTEROCOCCI-ENTEROLERT|10||MPN/100 mL|10|10|MICRO-MF|Microbiological Preparation for Membrane Filter Analysis|23-OCT-2019|16:20|Enterolert/QT|N.Reistad / G.Snorek| RQ-2019-09-23-47|TLH-2019-10-24-41|2131147|ENRE11 Sunday Bay|G5SD0094|23-OCT-2019|12:15|24-OCT-2019|15:28|31616|Fecal Coliforms-Membrane Filter|10|U|cfu/100 mL|10|10|MICRO-MF|Microbiological Preparation for Membrane Filter Analysis|23-OCT-2019|16:22|SM 9222 D|N.Reistad / G.Snorek| RQ-2019-09-23-47|TLH-2019-10-24-41|2131148|ENRE 11 at Huston Bay|G5SD0026|23-OCT-2019|12:40|24-OCT-2019|16:20|31649|ENTEROCOCCI-ENTEROLERT|10|U|MPN/100 mL|10|10|MICRO-MF|Microbiological Preparation for Membrane Filter Analysis|23-OCT-2019|16:20|Enterolert/QT|N.Reistad / G.Snorek| RQ-2019-09-23-47|TLH-2019-10-24-41|2131148|ENRE 11 at Huston Bay|G5SD0026|23-OCT-2019|12:40|24-OCT-2019|15:28|31616|Fecal Coliforms-Membrane Filter|10|U|cfu/100 mL|10|10|MICRO-MF|Microbiological Preparation for Membrane Filter Analysis|23-OCT-2019|16:22|SM 9222 D|N.Reistad / G.Snorek|