REQUEST_ID SAMPLE_SITE FIELD_ID STORET_STATION SAMPLE_DATE SAMPLE_TIME SAMPLE_ID PARAM_CODE PARAM_NAME RESULT VALUE_QUAL MDL UOM PQL LAB_COMMENTS PREP_DATE PREP_TIME ANALYSIS_DATE ANALYSIS_TIME ANALYSIS_METHOD SAMPLER RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152546 Total Alkalinity 0.65 U 0.65 mg CaCO3/L 2.5 02-04-2020 02:50 SM 2320 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152546 76 Turbidity 1.2 0.10 NTU 0.13 01-29-2020 17:38 EPA 180.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152546 940 Chloride 9.3 0.20 mg Cl/L 0.50 02-04-2020 21:41 EPA 300.0 Rev. 2.1 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152546 80 Color (true) 360 10 PCU 24 01-29-2020 19:00 SM 2120 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152546 951 Fluoride 0.039 I 0.035 mg F/L 0.10 02-04-2020 02:50 SM 4500 F-C-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152546 945 Sulfate 1.1 0.20 mg SO4/L 0.50 02-04-2020 21:41 EPA 300.0 Rev. 2.1 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152546 70300 TDS 110 15 mg/L 25 01-30-2020 14:40 SM 2540 C-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152546 530 TSS 2 U 2.0 mg/L 10 Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. 01-30-2020 14:40 SM 2540 D-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152547 Total Alkalinity 17 0.65 mg CaCO3/L 2.5 02-04-2020 03:01 SM 2320 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152547 76 Turbidity 2.0 0.10 NTU 0.13 01-29-2020 17:38 EPA 180.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152547 940 Chloride 19 0.20 mg Cl/L 0.50 02-04-2020 21:53 EPA 300.0 Rev. 2.1 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152547 80 Color (true) 160 5.0 PCU 12 01-29-2020 19:01 SM 2120 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152547 951 Fluoride 0.094 I 0.035 mg F/L 0.10 02-04-2020 03:01 SM 4500 F-C-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152547 945 Sulfate 5.9 0.20 mg SO4/L 0.50 02-04-2020 21:53 EPA 300.0 Rev. 2.1 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152547 70300 TDS 125 15 mg/L 25 01-30-2020 14:40 SM 2540 C-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152547 530 TSS 2 U 2.0 mg/L 10 Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. 01-30-2020 14:40 SM 2540 D-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152548 610 Ammonia-N 0.008 0.0020 mg N/L 0.0050 02-03-2020 14:02 EPA 350.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152548 630 NO2NO3-N 0.052 0.0040 mg N/L 0.010 02-04-2020 10:15 EPA 353.2 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152548 665 Total-P 0.017 0.0020 mg P/L 0.0050 02-03-2020 15:03 02-06-2020 13:47 EPA 365.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152548 625 Kjeldahl Nitrogen 0.91 0.080 mg N/L 0.20 02-05-2020 14:50 02-06-2020 11:55 EPA 351.2 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152548 680 Organic Carbon 43 0.50 mg C/L 1.0 02-03-2020 06:57 SM 5310 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152549 610 Ammonia-N 0.12 0.0020 mg N/L 0.0050 02-03-2020 14:03 EPA 350.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152549 630 NO2NO3-N 0.71 0.0040 mg N/L 0.010 02-04-2020 10:16 EPA 353.2 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152549 665 Total-P 0.30 0.0050 mg P/L 0.050 02-03-2020 15:03 02-05-2020 12:08 EPA 365.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152549 625 Kjeldahl Nitrogen 0.92 0.080 mg N/L 0.20 02-05-2020 14:50 02-06-2020 11:57 EPA 351.2 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152549 680 Organic Carbon 23 0.50 mg C/L 1.0 02-03-2020 06:02 SM 5310 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152550 671 O-Phosphate-P 0.007 I 0.0040 mg P/L 0.010 01-29-2020 15:41 EPA 365.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152551 671 O-Phosphate-P 0.26 0.0040 mg P/L 0.010 01-29-2020 14:54 EPA 365.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152552 Total Alkalinity 36 0.65 mg CaCO3/L 2.5 02-04-2020 03:13 SM 2320 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152552 76 Turbidity 4.0 0.10 NTU 0.13 01-29-2020 17:38 EPA 180.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152552 940 Chloride 25 0.20 mg Cl/L 0.50 02-04-2020 22:06 EPA 300.0 Rev. 2.1 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152552 80 Color (true) 270 7.5 PCU 18 01-29-2020 19:02 SM 2120 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152552 951 Fluoride 0.082 I 0.035 mg F/L 0.10 02-04-2020 03:13 SM 4500 F-C-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152552 945 Sulfate 6.5 0.20 mg SO4/L 0.50 02-04-2020 22:06 EPA 300.0 Rev. 2.1 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152552 70300 TDS 162 15 mg/L 25 01-30-2020 14:40 SM 2540 C-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152552 530 TSS 2 I 2.0 mg/L 10 Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. 01-30-2020 14:40 SM 2540 D-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152553 610 Ammonia-N 0.013 0.0020 mg N/L 0.0050 02-05-2020 12:41 EPA 350.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152553 630 NO2NO3-N 0.12 0.0040 mg N/L 0.010 02-04-2020 10:17 EPA 353.2 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152553 665 Total-P 0.18 0.0050 mg P/L 0.050 02-03-2020 15:03 02-05-2020 12:11 EPA 365.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152553 625 Kjeldahl Nitrogen 0.85 0.080 mg N/L 0.20 02-05-2020 14:50 02-06-2020 11:58 EPA 351.2 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152553 680 Organic Carbon 28 0.50 mg C/L 1.0 02-03-2020 07:52 SM 5310 B-2011 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152554 671 O-Phosphate-P 0.13 0.0040 mg P/L 0.010 01-29-2020 15:42 EPA 365.1 Rev. 2.0 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 99937 Sucralose 0.035 I 0.010 ug/L 0.040 01-30-2020 12:00 01-31-2020 01:00 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 AMPA 0.10 U 0.10 ug/L 0.40 01-30-2020 12:00 02-03-2020 22:06 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Acesulfame K 0.10 U 0.10 ug/L 0.40 01-30-2020 12:00 02-03-2020 16:27 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Endothall 0.25 U 0.25 ug/L 1.0 01-30-2020 12:00 02-03-2020 16:27 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Glufosinate 0.10 U 0.10 ug/L 0.40 01-30-2020 12:00 02-03-2020 22:06 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Glyphosate 0.10 U 0.10 ug/L 0.40 01-30-2020 12:00 02-03-2020 22:06 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 39730 2,4-D 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Acetaminophen 0.0080 U 0.0080 ug/L 0.032 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Acetamiprid 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Afidopyropen 0.0020 UJ 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Bentazon 8.0E-04 U 8.0E-04 ug/L 0.0032 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Benzovindiflupyr 0.0020 UJ 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Carbamazepine 8.0E-04 U 8.0E-04 ug/L 0.0032 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Clothianidin 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Dinotefuran 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Diuron 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Fenuron 0.016 U 0.016 ug/L 0.064 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Fluridone 8.0E-04 U 8.0E-04 ug/L 0.0032 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Hydrocodone 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Ibuprofen 0.020 U 0.020 ug/L 0.080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Imazapyr 0.0055 I 0.0040 ug/L 0.016 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Imidacloprid 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Linuron 0.0040 U 0.0040 ug/L 0.016 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 MCPP 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Mandestrobin 0.0020 UJ 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Naproxen 0.0080 U 0.0080 ug/L 0.032 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Primidone 0.0040 U 0.0040 ug/L 0.016 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Pyraclostrobin 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Thiamethoxam 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Tolfenpyrad 0.0020 U 0.0020 ug/L 0.0080 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Unnamed Branch @ CR 125 19010123 19010123 01-28-2020 11:18 2152572 Triclopyr 0.0040 U 0.0040 ug/L 0.016 J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon and imazapyr could not be assessed due to high concentration of parameter in the spiked sample. 01-30-2020 10:00 02-01-2020 19:57 EPA 8321B A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 46570 Hardness 15.7 0.35 mg/L 1.4 02-03-2020 16:20 SM 2340B A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1007 Barium 16.2 1.0 ug/L 4.0 01-30-2020 15:25 02-03-2020 16:20 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 916 Calcium 3.23 0.075 mg/L 0.30 01-30-2020 15:25 02-03-2020 16:20 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1045 Iron 750 30 ug/L 120 01-30-2020 15:25 02-03-2020 16:20 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 927 Magnesium 1.86 0.040 mg/L 0.16 01-30-2020 15:25 02-03-2020 16:20 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 937 Potassium 0.30 U 0.30 mg/L 1.2 01-30-2020 15:25 02-03-2020 16:20 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 929 Sodium 5.5 0.50 mg/L 2.0 01-30-2020 15:25 02-03-2020 16:20 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1092 Zinc 17 I 5.0 ug/L 20 01-30-2020 15:25 02-03-2020 16:20 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1105 Aluminum 480 5.0 ug/L 20 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1097 Antimony 0.061 I 0.050 ug/L 0.20 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1002 Arsenic 0.45 0.050 ug/L 0.20 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1022 Boron 12.5 2.0 ug/L 8.0 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-17-2020 20:18 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1027 Cadmium 0.034 I 0.020 ug/L 0.080 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1034 Chromium 0.64 I 0.40 ug/L 1.6 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1042 Copper 3.90 0.40 ug/L 0.80 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1051 Lead 1.03 0.20 ug/L 0.40 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1067 Nickel 0.65 I 0.50 ug/L 2.0 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-10-2020 18:41 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1147 Selenium 0.20 U 0.20 ug/L 0.80 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1077 Silver 0.010 U 0.010 ug/L 0.040 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-17-2020 20:18 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys River at SR 121 GA Line 19010002 19010002 01-28-2020 09:45 2152577 1059 Thallium 0.10 U 0.10 ug/L 0.40 The copper and lead results were confirmed in the undigested sample on 02/13/2020. 01-30-2020 15:25 02-07-2020 17:04 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 46570 Hardness 36.6 0.35 mg/L 1.4 02-03-2020 16:28 SM 2340B A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1007 Barium 30.0 1.0 ug/L 4.0 01-30-2020 15:25 02-03-2020 16:28 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 916 Calcium 8.71 0.075 mg/L 0.30 01-30-2020 15:25 02-03-2020 16:28 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1045 Iron 560 30 ug/L 120 01-30-2020 15:25 02-03-2020 16:28 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 927 Magnesium 3.61 0.040 mg/L 0.16 01-30-2020 15:25 02-03-2020 16:28 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 937 Potassium 1.7 0.30 mg/L 1.2 01-30-2020 15:25 02-03-2020 16:28 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 929 Sodium 12.5 0.50 mg/L 2.0 01-30-2020 15:25 02-03-2020 16:28 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1092 Zinc 8.1 I 5.0 ug/L 20 01-30-2020 15:25 02-03-2020 16:28 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1105 Aluminum 377 5.0 ug/L 20 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1097 Antimony 0.086 I 0.050 ug/L 0.20 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1002 Arsenic 0.42 0.050 ug/L 0.20 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1022 Boron 24.5 2.0 ug/L 8.0 01-30-2020 15:25 02-17-2020 17:29 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1027 Cadmium 0.023 I 0.020 ug/L 0.080 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1034 Chromium 0.70 I 0.40 ug/L 1.6 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1042 Copper 0.40 U 0.40 ug/L 0.80 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1051 Lead 0.37 I 0.20 ug/L 0.40 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1067 Nickel 0.76 I 0.50 ug/L 2.0 01-30-2020 15:25 02-10-2020 16:11 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1147 Selenium 0.20 U 0.20 ug/L 0.80 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1077 Silver 0.010 U 0.010 ug/L 0.040 01-30-2020 15:25 02-17-2020 17:29 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 St.Marys S Prong @ US 90 19010021 19010021 01-28-2020 10:50 2152578 1059 Thallium 0.10 U 0.10 ug/L 0.40 01-30-2020 15:25 02-07-2020 14:34 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 46570 Hardness 54.9 0.35 mg/L 1.4 02-03-2020 17:24 SM 2340B A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1007 Barium 18.7 1.0 ug/L 4.0 01-30-2020 15:25 02-03-2020 17:24 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 916 Calcium 15.4 0.075 mg/L 0.30 01-30-2020 15:25 02-03-2020 17:24 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1045 Iron 940 30 ug/L 120 01-30-2020 15:25 02-03-2020 17:24 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 927 Magnesium 3.97 0.040 mg/L 0.16 01-30-2020 15:25 02-03-2020 17:24 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 937 Potassium 2.9 0.30 mg/L 1.2 01-30-2020 15:25 02-03-2020 17:24 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 929 Sodium 17.1 0.50 mg/L 2.0 01-30-2020 15:25 02-03-2020 17:24 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1092 Zinc 9.7 I 5.0 ug/L 20 01-30-2020 15:25 02-03-2020 17:24 EPA 200.7 Rev. 4.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1105 Aluminum 309 5.0 ug/L 20 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1097 Antimony 0.15 I 0.050 ug/L 0.20 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1002 Arsenic 0.59 0.050 ug/L 0.20 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1022 Boron 47.0 2.0 ug/L 8.0 01-30-2020 15:25 02-17-2020 20:27 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1027 Cadmium 0.043 I 0.020 ug/L 0.080 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1034 Chromium 1.3 I 0.40 ug/L 1.6 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1042 Copper 0.70 I 0.40 ug/L 0.80 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1051 Lead 0.52 0.20 ug/L 0.40 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1067 Nickel 1.2 I 0.50 ug/L 2.0 01-30-2020 15:25 02-10-2020 18:50 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1147 Selenium 0.20 U 0.20 ug/L 0.80 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1077 Silver 0.010 U 0.010 ug/L 0.040 01-30-2020 15:25 02-17-2020 20:27 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis RQ-2020-01-27-13 Deep Creek @ US 90 19010085 19010085 01-28-2020 12:10 2152579 1059 Thallium 0.10 U 0.10 ug/L 0.40 01-30-2020 15:25 02-07-2020 17:14 EPA 200.8 Rev. 5.4 A.Kalmbacher, B.Davis