REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2020-01-06-46|TLH-2020-01-09-29|2148182|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|20:18||Total Alkalinity|110||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148182|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|09-JAN-2020|15:29|76|Turbidity|2.2||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148182|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|13-JAN-2020|22:23|940|Chloride|120||mg Cl/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148182|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|09-JAN-2020|15:19|80|Color (true)|40||PCU|2.5|6.0|||||SM 2120 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148182|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|20:18|951|Fluoride|0.27||mg F/L|0.035|0.10|||||SM 4500 F-C-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148182|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|13-JAN-2020|22:23|945|Sulfate|140||mg SO4/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148182|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|10-JAN-2020|16:20|70300|TDS|532||mg/L|15|25|||||SM 2540 C-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148182|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|10-JAN-2020|16:20|530|TSS|4|I|mg/L|2.0|10|||||SM 2540 D-2011|Nicole Reistad, Chris Hormuth|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2020-01-06-46|TLH-2020-01-09-29|2148183|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|14-JAN-2020|13:01|610|Ammonia-N|0.077||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148183|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|13-JAN-2020|10:42|630|NO2NO3-N|1.0||mg N/L|0.0080|0.020|||||EPA 353.2 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148183|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|17-JAN-2020|14:58|665|Total-P|0.12||mg P/L|0.0050|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|15-JAN-2020|01:48|EPA 365.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148183|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|13:03|625|Kjeldahl Nitrogen|1.2||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|15-JAN-2020|11:30|EPA 351.2 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148183|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|14-JAN-2020|02:37|680|Organic Carbon|12||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148184|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|09-JAN-2020|17:40|671|O-Phosphate-P|0.083||mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148185|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|21:46||Total Alkalinity|136||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148185|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|09-JAN-2020|15:29|76|Turbidity|1.2||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148185|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|13-JAN-2020|22:35|940|Chloride|190||mg Cl/L|2.0|5.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148185|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|09-JAN-2020|15:20|80|Color (true)|38|A|PCU|2.5|6.0|||||SM 2120 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148185|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|21:46|951|Fluoride|0.42||mg F/L|0.035|0.10|||||SM 4500 F-C-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148185|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|13-JAN-2020|22:35|945|Sulfate|160||mg SO4/L|2.0|5.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148185|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|10-JAN-2020|16:20|70300|TDS|730|A|mg/L|15|25|||||SM 2540 C-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148185|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|10-JAN-2020|16:20|530|TSS|2|UA|mg/L|2.0|10|||||SM 2540 D-2011|Nicole Reistad, Chris Hormuth|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2020-01-06-46|TLH-2020-01-09-29|2148186|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|14-JAN-2020|13:03|610|Ammonia-N|0.035||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148186|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|13-JAN-2020|10:25|630|NO2NO3-N|0.57||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148186|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|17-JAN-2020|14:59|665|Total-P|0.14||mg P/L|0.0050|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|15-JAN-2020|01:48|EPA 365.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148186|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|13:05|625|Kjeldahl Nitrogen|0.84||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|15-JAN-2020|11:30|EPA 351.2 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148186|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|14-JAN-2020|00:02|680|Organic Carbon|11||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148187|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|09-JAN-2020|18:03|671|O-Phosphate-P|0.11||mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148188|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|15-JAN-2020|22:01||Total Alkalinity|280||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148188|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|09-JAN-2020|15:29|76|Turbidity|5.2|A|NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148188|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|13-JAN-2020|23:11|940|Chloride|38||mg Cl/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148188|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|09-JAN-2020|15:21|80|Color (true)|45||PCU|2.5|6.0|||||SM 2120 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148188|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|15-JAN-2020|22:01|951|Fluoride|0.17||mg F/L|0.035|0.10|||||SM 4500 F-C-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148188|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|13-JAN-2020|23:11|945|Sulfate|11||mg SO4/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148188|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|10-JAN-2020|16:20|70300|TDS|391||mg/L|15|25|||||SM 2540 C-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148188|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|10-JAN-2020|16:20|530|TSS|2|I|mg/L|2.0|10|||||SM 2540 D-2011|Nicole Reistad, Chris Hormuth|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2020-01-06-46|TLH-2020-01-09-29|2148189|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|14-JAN-2020|13:15|610|Ammonia-N|0.061||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148189|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|13-JAN-2020|10:26|630|NO2NO3-N|0.22||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148189|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|21-JAN-2020|13:24|665|Total-P|0.019||mg P/L|0.0020|0.0050|365.1 (MARCH 1983)|Automated, ascorbic acid|15-JAN-2020|01:48|EPA 365.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148189|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|16-JAN-2020|13:06|625|Kjeldahl Nitrogen|0.82||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|15-JAN-2020|11:30|EPA 351.2 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148189|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|14-JAN-2020|02:50|680|Organic Carbon|16||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-29|2148190|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|09-JAN-2020|18:04|671|O-Phosphate-P|0.008|I|mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|14-JAN-2020|12:00|99937|Sucralose|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth|MDL elevated due to matrix interference. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|09-JAN-2020|17:27||AMPA|1.5||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|10-JAN-2020|18:33||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|10-JAN-2020|18:33||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|09-JAN-2020|17:27||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|09-JAN-2020|17:27||Glyphosate|1.5||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25|39730|2,4-D|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Afidopyropen|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Bentazon|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Benzovindiflupyr|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Clothianidin|0.21||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Diuron|0.0035|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Imazapyr|0.030||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Imidacloprid|0.84||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Mandestrobin|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Thiamethoxam|0.29||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148206|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|11-JAN-2020|00:25||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|14-JAN-2020|12:11|99937|Sucralose|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth|MDL elevated due to matrix interference. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|09-JAN-2020|17:38||AMPA|1.4||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|10-JAN-2020|18:46||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|10-JAN-2020|18:46||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|09-JAN-2020|17:38||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|09-JAN-2020|17:38||Glyphosate|0.53||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00|39730|2,4-D|0.024|J|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Afidopyropen|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Bentazon|0.0099||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Benzovindiflupyr|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Clothianidin|0.19||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Diuron|0.014||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Fenuron|0.17||ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Imazapyr|0.015|I|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Imidacloprid|0.69||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Mandestrobin|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Thiamethoxam|0.42||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148207|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|11-JAN-2020|01:00||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|13-JAN-2020|23:09|99937|Sucralose|0.016|I|ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|09-JAN-2020|17:59||AMPA|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|10-JAN-2020|19:14||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|10-JAN-2020|19:14||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|09-JAN-2020|17:59||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|09-JAN-2020|17:59||Glyphosate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|09-JAN-2020|16:00|EPA 8321B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34|39730|2,4-D|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Afidopyropen|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Bentazon|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Benzovindiflupyr|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Fluridone|0.011||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Imazapyr|0.017||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Imidacloprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Mandestrobin|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-35|2148208|MyrtleSlough@PineIsland|G3SD0095|08-JAN-2020|11:40|11-JAN-2020|01:34||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|10-JAN-2020|12:00|EPA 8321B|Nicole Reistad, Chris Hormuth|J - second source check standards for some analytes were not available for analysis. MS accuracy for bentazon could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|15:52|46570|Hardness|301||mg/L|0.35|1.4|||||SM 2340B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|15:52|1007|Barium|41.6||ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|15:52|916|Calcium|85.8||mg/L|0.075|0.30|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|15:52|1045|Iron|330||ug/L|30|120|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|15:52|927|Magnesium|21.1||mg/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|15:52|937|Potassium|14.6||mg/L|0.30|1.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|15:52|929|Sodium|59.9||mg/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|15-JAN-2020|15:52|1092|Zinc|5.2|I|ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1105|Aluminum|92||ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1097|Antimony|1.54||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1002|Arsenic|0.86||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|21-JAN-2020|14:48|1022|Boron|86.7||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1027|Cadmium|0.030|I|ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1034|Chromium|0.73|I|ug/L|0.40|1.6|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|17-JAN-2020|17:04|1042|Copper|1.44||ug/L|0.40|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1051|Lead|0.20|U|ug/L|0.20|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1067|Nickel|2.9||ug/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1147|Selenium|0.44|I|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1077|Silver|0.010|U|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148209|Hog Bay @ CR 763|G3SD0096|08-JAN-2020|11:00|16-JAN-2020|14:34|1059|Thallium|0.14|I|ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|16:00|46570|Hardness|410||mg/L|0.35|1.4|||||SM 2340B|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|16:00|1007|Barium|41.5||ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|16:00|916|Calcium|115||mg/L|0.075|0.30|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|16:00|1045|Iron|130||ug/L|30|120|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|16:00|927|Magnesium|29.9||mg/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|16:00|937|Potassium|11.5||mg/L|0.30|1.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|16:00|929|Sodium|83.1||mg/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|15-JAN-2020|16:00|1092|Zinc|5.0|U|ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.7 Rev. 4.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1105|Aluminum|30||ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1097|Antimony|0.69||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1002|Arsenic|1.15||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|21-JAN-2020|15:29|1022|Boron|68.6||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1027|Cadmium|0.101||ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1034|Chromium|0.40|U|ug/L|0.40|1.6|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|17-JAN-2020|17:14|1042|Copper|1.20||ug/L|0.40|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1051|Lead|0.20|U|ug/L|0.20|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1067|Nickel|2.0||ug/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1147|Selenium|0.22|I|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1077|Silver|0.010|U|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth| RQ-2020-01-06-46|TLH-2020-01-09-36|2148210|HawthorneCreek@Reynolds|G3SD0011|08-JAN-2020|10:10|16-JAN-2020|14:43|1059|Thallium|0.10|U|ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|14-JAN-2020|15:20|EPA 200.8 Rev. 5.4|Nicole Reistad, Chris Hormuth|