REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49||3-Hydroxycarbofuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49||Aldicarb|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49||Aldicarb Sulfone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49||Aldicarb Sulfoxide|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49|39750|Carbaryl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49|81405|Carbofuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49||Methiocarb|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49|39051|Methomyl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49||Oxamyl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241121|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|01:49||Propoxur|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|28-APR-2021|22:29|99937|Sucralose|0.21||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|21-APR-2021|12:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|21-APR-2021|14:53||AMPA|0.10|UJ|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|21-APR-2021|12:00|EPA 8321B|Dany Berser|Results confirmed in sample duplicate. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|21-APR-2021|14:53||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|21-APR-2021|12:00|EPA 8321B|Dany Berser|Results confirmed in sample duplicate. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|21-APR-2021|14:53||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|21-APR-2021|12:00|EPA 8321B|Dany Berser|Results confirmed in sample duplicate. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|21-APR-2021|14:53||Glufosinate|0.10|UJ|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|21-APR-2021|12:00|EPA 8321B|Dany Berser|Results confirmed in sample duplicate. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|21-APR-2021|14:53||Glyphosate|0.10|UJ|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|21-APR-2021|12:00|EPA 8321B|Dany Berser|Results confirmed in sample duplicate. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43|39730|2,4-D|0.039||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|03-MAY-2021|10:38||Bentazon|0.095||ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Fluridone|0.072||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Imazapyr|0.24||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Imidacloprid|0.0063|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-52|2241122|COCAT41|COCAT41|19-APR-2021|11:41|30-APR-2021|16:43||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|20-APR-2021|14:00|EPA 8321B|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|01:38||Chlordane|5.5|U|ng/L|5.5|22|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8276|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|01:38||Toxaphene|33|U|ng/L|33|130|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8276|Dany Berser| RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39330|Aldrin|0.71|U|ng/L|0.71|3.5|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39337|Alpha-BHC|0.11|U|ng/L|0.11|0.55|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Alpha-Chlordane|0.22|U|ng/L|0.22|1.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39338|Beta-BHC|0.11|U|ng/L|0.11|0.55|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Beta-Cyfluthrin|1.4|U|ng/L|1.4|6.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Bifenthrin|0.55|U|ng/L|0.55|2.7|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|05-MAY-2021|17:31|70314|Chlorothalonil|0.55|UQJ|ng/L|0.55|8.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|30-APR-2021|09:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Cis-Nonachlor|0.22|U|ng/L|0.22|1.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|3781|Cypermethrin|1.6|U|ng/L|1.6|8.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|05-MAY-2021|17:31|39310|DDD-p,p'|0.27|UQJ|ng/L|0.27|1.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|30-APR-2021|09:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39320|DDE-p,p'|0.22|U|ng/L|0.22|1.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|05-MAY-2021|17:31|39300|DDT-p,p'|0.27|UQJ|ng/L|0.27|1.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|30-APR-2021|09:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Dacthal|0.16|U|ng/L|0.16|0.82|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|34259|Delta-BHC|0.44|U|ng/L|0.44|2.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Deltamethrin|1.4|UJ|ng/L|1.4|6.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Dichlobenil|0.11|U|ng/L|0.11|0.55|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Dicofol|1.4|U|ng/L|1.4|6.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39380|Dieldrin|0.44|U|ng/L|0.44|2.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|34361|Endosulfan I|0.44|U|ng/L|0.44|2.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|34356|Endosulfan II|0.44|U|ng/L|0.44|2.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|34351|Endosulfan Sulfate|0.33|U|ng/L|0.33|1.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39390|Endrin|0.44|U|ng/L|0.44|2.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|34366|Endrin Aldehyde|0.82|U|ng/L|0.82|4.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Endrin Ketone|0.44|U|ng/L|0.44|2.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Esfenvalerate|0.82|UJ|ng/L|0.82|4.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Ethalfluralin|0.16|U|ng/L|0.16|0.82|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Fenpropathrin|0.27|U|ng/L|0.27|1.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39340|Gamma-BHC|0.14|U|ng/L|0.14|0.68|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Gamma-Chlordane|0.22|U|ng/L|0.22|1.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39410|Heptachlor|0.22|U|ng/L|0.22|1.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39420|Heptachlor Epoxide|0.27|U|ng/L|0.27|1.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Hexachlorobenzene|1.1|U|ng/L|1.1|5.5|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Kepone|5.5|U|ng/L|5.5|27|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Lambda-Cyhalothrin|0.82|UJ|ng/L|0.82|4.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||MGK-264|0.22|UJ|ng/L|0.22|1.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39480|Methoxychlor|0.33|U|ng/L|0.33|1.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|39755|Mirex|0.33|UJ|ng/L|0.33|1.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|79191|Permethrin|1.7|U|ng/L|1.7|8.7|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Phenothrin|0.98|UJ|ng/L|0.98|4.9|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Piperonyl Butoxide|1.5||ng/L|0.16|0.82|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Prallethrin|2.2|U|ng/L|2.2|11|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Tau-Fluvalinate|0.27|U|ng/L|0.27|1.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Tetramethrin|0.82|UJ|ng/L|0.82|4.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Trans-Nonachlor|0.22|U|ng/L|0.22|1.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56||Triclosan Methyl|0.16|U|ng/L|0.16|0.82|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241123|COCAT41|COCAT41|19-APR-2021|11:41|26-APR-2021|20:56|81284|Trifluralin|0.22|U|ng/L|0.22|1.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|23-APR-2021|08:00|EPA 8270E|Dany Berser|Sample expired for some analytes due to need for re-extraction. Reported results qualified with J for those analytes due to surrogate below control limits in the re-extraction; the sample was subsequently re-extracted and re-analyzed one more time (after expiration) with acceptable surrogate recovery and the same analytical results were obtained. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Acetochlor|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Alachlor|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|82184|Ametryn|0.74|I|ng/L|0.60|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|39033|Atrazine|21||ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Atrazine Desethyl|4.5|I|ng/L|1.5|6.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Azinphos Methyl|2.0|U|ng/L|2.0|8.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Azoxystrobin|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Bromacil|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Butylate|0.40|U|ng/L|0.40|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Caffeine|7.5|UJ|ng/L|7.5|30|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Carbophenothion|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Carfentrazone Ethyl|0.10|U|ng/L|0.10|0.40|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|38932|Chlorpyrifos Ethyl|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|38740|Chlorpyrifos Methyl|0.050|U|ng/L|0.050|0.20|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Cyanazine|3.3|U|ng/L|3.3|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Demeton|1.5|U|ng/L|1.5|6.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Diazinon|0.13|U|ng/L|0.13|0.50|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Difenoconazole|0.60|U|ng/L|0.60|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Dimethenamid|0.10|U|ng/L|0.10|0.40|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|81888|Disulfoton|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Dithiopyr|0.22|I|ng/L|0.18|0.70|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||EPTC|1.3|U|ng/L|1.3|5.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|39398|Ethion|0.15|U|ng/L|0.15|0.60|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|81758|Ethoprop|0.10|U|ng/L|0.10|0.40|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fenamiphos|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fenbuconazole|0.13|U|ng/L|0.13|0.50|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fipronil|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fipronil Desulfinyl|0.13|U|ng/L|0.13|0.50|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fipronil Sulfide|0.15|U|ng/L|0.15|0.60|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fipronil Sulfone|0.34|I|ng/L|0.15|0.60|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fluazifop-P-butyl|0.10|U|ng/L|0.10|0.40|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fludioxonil|0.13|U|ng/L|0.13|0.50|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Flumioxazin|1.8|U|ng/L|1.8|7.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Flutolanil|0.77||ng/L|0.10|0.40|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fluxapyroxad|1.2||ng/L|0.10|0.40|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Fonofos|0.20|U|ng/L|0.20|0.80|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|38815|Hexazinone|2.7||ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Imazalil|0.75|U|ng/L|0.75|3.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Iprodione|0.60|U|ng/L|0.60|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|39530|Malathion|0.35|U|ng/L|0.35|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Metalaxyl|0.75|U|ng/L|0.75|3.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Metolachlor|0.35|U|ng/L|0.35|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|81408|Metribuzin|3.3|U|ng/L|3.3|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|39610|Mevinphos|1.1|U|ng/L|1.1|4.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Molinate|0.30|U|ng/L|0.30|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Myclobutanil|0.92|I|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Naled|1.5|U|ng/L|1.5|6.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|78064|Norflurazon|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Oxadiazon|2.6||ng/L|0.30|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Oxyfluorfen|0.15|U|ng/L|0.15|0.60|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Parathion Ethyl|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Parathion Methyl|0.55|U|ng/L|0.55|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Pendimethalin|1.0|U|ng/L|1.0|4.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|46313|Phorate|0.53|U|ng/L|0.53|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Prodiamine|0.18|UJ|ng/L|0.18|0.70|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|39056|Prometon|0.91|U|ng/L|0.91|3.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|39057|Prometryn|0.20|U|ng/L|0.20|0.80|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Pronamide|0.15|U|ng/L|0.15|0.60|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Propiconazole|1.2|I|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Pyriproxyfen|0.13|U|ng/L|0.13|0.50|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|39055|Simazine|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Sulfentrazone|5.7||ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Tebuconazole|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48|82088|Terbufos|0.10|U|ng/L|0.10|0.40|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-03-29-63|TLH-2021-04-20-53|2241124|COCAT41|COCAT41|19-APR-2021|11:41|27-APR-2021|15:48||Terbuthylazine|0.43|U|ng/L|0.43|1.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|23-APR-2021|08:00|EPA 8270E|Dany Berser|Refer to the Lab Analysis Report for an explanation of QC Codes.