REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|10-JUN-2021|23:47||AMPA|1.0|U|ug/L|1.0|4.0|LC-FILTER|Filtration of samples prior to analysis|10-JUN-2021|13:00|EPA 8321B|John Barrington, Gary Snorek|MDL for some parameters elevated due to matrix interference. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|10-JUN-2021|18:53||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|10-JUN-2021|13:00|EPA 8321B|John Barrington, Gary Snorek|MDL for some parameters elevated due to matrix interference. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|10-JUN-2021|18:53||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|10-JUN-2021|13:00|EPA 8321B|John Barrington, Gary Snorek|MDL for some parameters elevated due to matrix interference. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|10-JUN-2021|23:47||Glufosinate|1.0|U|ug/L|1.0|4.0|LC-FILTER|Filtration of samples prior to analysis|10-JUN-2021|13:00|EPA 8321B|John Barrington, Gary Snorek|MDL for some parameters elevated due to matrix interference. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|10-JUN-2021|23:47||Glyphosate|1.0|U|ug/L|1.0|4.0|LC-FILTER|Filtration of samples prior to analysis|10-JUN-2021|13:00|EPA 8321B|John Barrington, Gary Snorek|MDL for some parameters elevated due to matrix interference. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|11-JUN-2021|07:21||Sucralose|0.19||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|10-JUN-2021|13:00|EPA 8321B|John Barrington, Gary Snorek|MDL for some parameters elevated due to matrix interference. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21|39730|2,4-D|0.20||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Bentazon|0.027||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Clothianidin|0.0035|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Diuron|0.053||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Fluridone|0.030||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Imazapyr|0.11||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Imidacloprid|0.13||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||MCPP|0.014||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Thiamethoxam|0.0030|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-05-03-63|TLH-2021-06-09-76|2253881|HendryCreekHouse1Upstrm|G1SD0118|08-JUN-2021|10:15|20-JUN-2021|23:21||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|14-JUN-2021|09:00|EPA 8321B|John Barrington, Gary Snorek|MS accuracy for imazapyr could not be assessed due to high concentration of parameter in the spiked sample.