REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2021-08-09-68|TLH-2021-08-04-91|2267208|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|05-AUG-2021|17:46||Total Alkalinity|13||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267208|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|04-AUG-2021|15:23|76|Turbidity|4.5||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267208|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|11-AUG-2021|20:05|940|Chloride|25||mg Cl/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267208|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|04-AUG-2021|16:07|80|Color (true)|520||PCU|12|30|||||SM 2120 B-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267208|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|05-AUG-2021|17:46|951|Fluoride|0.086|I|mg F/L|0.035|0.10|||||SM 4500 F-C-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267208|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|11-AUG-2021|20:05|945|Sulfate|8.0||mg SO4/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267208|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|06-AUG-2021|15:32|70300|TDS|186||mg/L|15|25|||||SM 2540 C-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267208|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|06-AUG-2021|15:32|530|TSS|8|I|mg/L|2.0|10|||||SM 2540 D-2011|Nicole Reistad, Thomas Baker|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2021-08-09-68|TLH-2021-08-04-91|2267209|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|05-AUG-2021|18:01||Total Alkalinity|278||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267209|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|04-AUG-2021|15:23|76|Turbidity|6.3||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267209|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|11-AUG-2021|20:17|940|Chloride|56||mg Cl/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267209|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|04-AUG-2021|16:02|80|Color (true)|79||PCU|2.5|6.0|||||SM 2120 B-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267209|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|05-AUG-2021|18:01|951|Fluoride|0.32||mg F/L|0.035|0.10|||||SM 4500 F-C-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267209|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|11-AUG-2021|20:17|945|Sulfate|35||mg SO4/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267209|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|06-AUG-2021|15:32|70300|TDS|457|A|mg/L|15|25|||||SM 2540 C-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267209|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|06-AUG-2021|15:32|530|TSS|5|IA|mg/L|2.0|10|||||SM 2540 D-2011|Nicole Reistad, Thomas Baker|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2021-08-09-68|TLH-2021-08-04-91|2267210|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|12-AUG-2021|11:27|610|Ammonia-N|0.021||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267210|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|06-AUG-2021|10:23|630|NO2NO3-N|0.062||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267210|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|18-AUG-2021|14:31|665|Total-P|0.24||mg P/L|0.0050|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|13-AUG-2021|15:00|EPA 365.1 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267210|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|25-AUG-2021|09:41|625|Kjeldahl Nitrogen|2.1||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|24-AUG-2021|13:34|EPA 351.2 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267210|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|14-AUG-2021|06:48|680|Organic Carbon|43||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267211|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|12-AUG-2021|11:28|610|Ammonia-N|0.024||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267211|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|06-AUG-2021|10:24|630|NO2NO3-N|0.040||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267211|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|18-AUG-2021|14:32|665|Total-P|0.39|J|mg P/L|0.0050|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|13-AUG-2021|15:00|EPA 365.1 Rev. 2.0|Nicole Reistad, Thomas Baker|Total-P: Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-91|2267211|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|25-AUG-2021|09:43|625|Kjeldahl Nitrogen|0.77||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|24-AUG-2021|13:34|EPA 351.2 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267211|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|14-AUG-2021|07:28|680|Organic Carbon|13||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267212|Bee Branch @ Loblolly Bay Rd|G3SD0085|03-AUG-2021|09:30|04-AUG-2021|15:26|671|O-Phosphate-P|0.13||mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-91|2267213|Bee Branch @ 78|G3SD0188|03-AUG-2021|10:45|04-AUG-2021|15:27|671|O-Phosphate-P|0.19||mg P/L|0.0040|0.010|||||EPA 365.1 Rev. 2.0|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|05-AUG-2021|20:22||AMPA|0.14|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|05-AUG-2021|13:38||Acesulfame K|0.12|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|05-AUG-2021|13:38||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|05-AUG-2021|20:22||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|05-AUG-2021|20:22||Glyphosate|0.19|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|05-AUG-2021|13:38||Sucralose|0.10||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52|39730|2,4-D|0.44||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Bentazon|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Imazapyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Imidacloprid|0.031|J|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||MCPP|0.0058|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Thiamethoxam|0.0020|UJ|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267226|PalmCreek@LeeCivicCtr|G3SD0190|03-AUG-2021|08:25|09-AUG-2021|23:52||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|06-AUG-2021|09:10||AMPA|0.28|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|05-AUG-2021|13:52||Acesulfame K|0.17|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|05-AUG-2021|13:52||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|06-AUG-2021|09:10||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|06-AUG-2021|09:10||Glyphosate|0.65||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|05-AUG-2021|13:52||Sucralose|0.36||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01|39730|2,4-D|0.038||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Bentazon|0.017||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Carbamazepine|0.0012|I|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Fluridone|0.0034||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Imazapyr|0.021||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Imidacloprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Primidone|0.015|I|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267227|Palm Creek|G3SD0163|03-AUG-2021|08:40|10-AUG-2021|01:01||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|06-AUG-2021|09:20||AMPA|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|05-AUG-2021|14:06||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|05-AUG-2021|14:06||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|06-AUG-2021|09:20||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|06-AUG-2021|09:20||Glyphosate|0.12|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|05-AUG-2021|14:06||Sucralose|0.12||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|05-AUG-2021|10:30|EPA 8321B|Nicole Reistad, Thomas Baker| RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36|39730|2,4-D|0.0032|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Bentazon|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Dinotefuran|0.0064|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Imazapyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Imidacloprid|0.0027|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample. RQ-2021-08-09-68|TLH-2021-08-04-97|2267228|Pollywog Creek @ SR 78|G3SD0098|03-AUG-2021|10:05|10-AUG-2021|01:36||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|09-AUG-2021|08:30|EPA 8321B|Nicole Reistad, Thomas Baker|MS accuracy for 2,4-D could not be assessed due to high concentration of parameter in the spiked sample.