REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2021-11-15-46|TLH-2021-11-17-86|2290141|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|18-NOV-2021|21:50||Total Alkalinity|61|A|mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290141|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|17-NOV-2021|15:13|76|Turbidity|3.4||NTU|0.10|0.13|||||EPA 180.1 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290141|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|22-NOV-2021|22:51|940|Chloride|30||mg Cl/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290141|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|17-NOV-2021|16:07|80|Color (true)|160||PCU|12|30|||||SM 2120 B-2011|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290141|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|18-NOV-2021|21:39|951|Fluoride|0.48||mg F/L|0.035|0.10|||||SM 4500 F-C-2011|Thomas Baker, Monica Jaeger|Batch matrix spike recoveries are unavailable because of high analyte concentration in the QC sample. RQ-2021-11-15-46|TLH-2021-11-17-86|2290141|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|22-NOV-2021|22:51|945|Sulfate|63||mg SO4/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290141|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|18-NOV-2021|15:56|70300|TDS|250|AJ|mg/L|15|25|||||SM 2540 C-2011|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-86|2290141|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|18-NOV-2021|15:56|530|TSS|4|IA|mg/L|2.0|10|||||SM 2540 D-2011|Thomas Baker, Monica Jaeger|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2021-11-15-46|TLH-2021-11-17-86|2290142|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|14:50|610|Ammonia-N|0.029||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290142|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|19-NOV-2021|11:06|630|NO2NO3-N|0.57||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290142|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|24-NOV-2021|11:39|665|Total-P|0.52||mg P/L|0.0050|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|23-NOV-2021|12:38|EPA 365.1 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290142|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|12:00|625|Kjeldahl Nitrogen|1.0||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|30-NOV-2021|12:32|EPA 351.2 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290142|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|01-DEC-2021|22:54|680|Organic Carbon|20||mg C/L|0.50|1.0|||||SM 5310 B-2011|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-86|2290143|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|17-NOV-2021|15:16|671|O-Phosphate-P|0.44||mg P/L|0.0080|0.020|||||EPA 365.1 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|19-NOV-2021|10:15||AMPA|0.59||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|19-NOV-2021|19:17||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|19-NOV-2021|19:17||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|19-NOV-2021|10:15||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|19-NOV-2021|10:15||Glyphosate|0.54||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|19-NOV-2021|19:17||Sucralose|0.50||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12|39730|2,4-D|0.071||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Bentazon|0.0097||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Carbamazepine|0.0015|I|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Clothianidin|0.044||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Dinotefuran|0.0087||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Diuron|0.029||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Fluridone|8.2E-04|I|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Imazapyr|0.068||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Imidacloprid|0.16||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||MCPP|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Primidone|0.0040|UJ|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12|39760|Silvex|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Thiamethoxam|0.12||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290146|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|20-NOV-2021|17:12||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47||3-Hydroxycarbofuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47||Aldicarb|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47||Aldicarb Sulfone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47||Aldicarb Sulfoxide|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47|39750|Carbaryl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47|81405|Carbofuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47||Methiocarb|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47|39051|Methomyl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47||Oxamyl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290147|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|17:47||Propoxur|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|No sample available for matrix spikes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|19-NOV-2021|10:26||AMPA|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|19-NOV-2021|19:32||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|19-NOV-2021|19:32||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|19-NOV-2021|10:26||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|19-NOV-2021|10:26||Glyphosate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|19-NOV-2021|19:32||Sucralose|0.010|U|ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|19-NOV-2021|08:30|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22|39730|2,4-D|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Bentazon|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Fenuron|0.016|U|ug/L|0.016|0.064|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Imazapyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Imidacloprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||MCPP|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Primidone|0.0040|UJ|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22|39760|Silvex|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-89|2290148|FB|FB_11162021|16-NOV-2021|14:25|20-NOV-2021|18:22||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|17-NOV-2021|14:30|EPA 8321B|Thomas Baker, Monica Jaeger|Matrix spikes are not available due to technical problems. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Acetochlor|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Alachlor|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|82184|Ametryn|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|39033|Atrazine|3.4||ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|22-NOV-2021|18:08||Atrazine Desethyl|2.7|I|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Azinphos Methyl|1.9|UJ|ng/L|1.9|7.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Azoxystrobin|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|14:42||Bromacil|86|J|ng/L|2.4|9.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Butylate|0.39|U|ng/L|0.39|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Caffeine|10|I|ng/L|7.2|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Carbophenothion|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Carfentrazone Ethyl|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Chlorfenapyr|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|38932|Chlorpyrifos Ethyl|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|38740|Chlorpyrifos Methyl|0.048|U|ng/L|0.048|0.19|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Coumaphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Cyanazine|3.1|U|ng/L|3.1|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Cyprodinil|0.35|I|ng/L|0.097|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Demeton|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Diazinon|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|22-NOV-2021|18:08||Difenoconazole|0.58|UJ|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Dimethenamid|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Dimethomorph|0.17|UJ|ng/L|0.17|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|81888|Disulfoton|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Dithiopyr|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||EPTC|1.2|U|ng/L|1.2|4.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|39398|Ethion|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|81758|Ethoprop|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Etridiazole|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fenamiphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fenbuconazole|0.73||ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fipronil|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fipronil Desulfinyl|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fipronil Sulfide|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fipronil Sulfone|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fluazifop-P-butyl|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fludioxonil|0.35|I|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Flumioxazin|1.7|U|ng/L|1.7|6.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Flutolanil|0.22|I|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|22-NOV-2021|18:08||Fluxapyroxad|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Fonofos|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|38815|Hexazinone|44||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Imazalil|0.72|U|ng/L|0.72|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|22-NOV-2021|18:08||Iprodione|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Loratadine|0.097|UJ|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|39530|Malathion|0.34|U|ng/L|0.34|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|14:42||Metalaxyl|33||ng/L|3.6|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Metolachlor|15||ng/L|0.34|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|81408|Metribuzin|3.1|U|ng/L|3.1|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|39610|Mevinphos|1.0|U|ng/L|1.0|4.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Molinate|0.29|U|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Myclobutanil|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Naled|1.4|UJ|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Napropamide|0.39|U|ng/L|0.39|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|14:42|78064|Norflurazon|110||ng/L|2.4|9.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Oxadiazon|0.29|U|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Oxyfluorfen|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Parathion Ethyl|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Parathion Methyl|0.53|U|ng/L|0.53|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Pendimethalin|0.97|U|ng/L|0.97|3.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Phenytoin|3.4|UJ|ng/L|3.4|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|46313|Phorate|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Prodiamine|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|39056|Prometon|0.87|U|ng/L|0.87|3.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|39057|Prometryn|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Pronamide|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Propanil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Propargite|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Propiconazole|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Pyraflufen Ethyl|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Pyridaben|0.43|U|ng/L|0.43|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Pyriproxyfen|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|39055|Simazine|20||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Stirophos|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|22-NOV-2021|18:08||Sulfentrazone|7.5||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|22-NOV-2021|18:08||Tebuconazole|0.78|I|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15|82088|Terbufos|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Terbuthylazine|0.41|U|ng/L|0.41|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Thiobencarb|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290149|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|17:15||Triadimefon|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|24-NOV-2021|15:22||Chlordane|2.6|U|ng/L|2.6|13|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8276|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|24-NOV-2021|15:22||Toxaphene|16|U|ng/L|16|78|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8276|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39330|Aldrin|0.67|U|ng/L|0.67|3.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39337|Alpha-BHC|0.10|U|ng/L|0.10|0.52|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Alpha-Chlordane|0.21|U|ng/L|0.21|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39338|Beta-BHC|0.10|UJ|ng/L|0.10|0.52|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Beta-Cyfluthrin|1.3|U|ng/L|1.3|6.5|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Bifenthrin|0.52|U|ng/L|0.52|2.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39786|Carbophenothion|0.93|U|ng/L|0.93|4.7|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|70314|Chlorothalonil|0.52|UJ|ng/L|0.52|7.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Cis-Nonachlor|0.21|U|ng/L|0.21|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|3781|Cypermethrin|1.6|U|ng/L|1.6|7.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39310|DDD-p,p'|0.26|U|ng/L|0.26|1.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39320|DDE-p,p'|0.21|U|ng/L|0.21|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39300|DDT-p,p'|0.26|U|ng/L|0.26|1.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Dacthal|0.16|U|ng/L|0.16|0.78|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|34259|Delta-BHC|0.41|UJ|ng/L|0.41|2.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Dicofol|1.3|U|ng/L|1.3|6.5|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39380|Dieldrin|0.41|U|ng/L|0.41|2.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|34361|Endosulfan I|0.41|U|ng/L|0.41|2.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|34356|Endosulfan II|0.41|U|ng/L|0.41|2.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|34351|Endosulfan Sulfate|0.31|U|ng/L|0.31|1.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39390|Endrin|0.41|U|ng/L|0.41|2.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|34366|Endrin Aldehyde|0.78|U|ng/L|0.78|3.9|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Endrin Ketone|0.41|UJ|ng/L|0.41|2.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Ethalfluralin|0.16|U|ng/L|0.16|0.78|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39340|Gamma-BHC|0.13|UJ|ng/L|0.13|0.65|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Gamma-Chlordane|0.21|U|ng/L|0.21|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39410|Heptachlor|0.21|U|ng/L|0.21|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39420|Heptachlor Epoxide|0.26|U|ng/L|0.26|1.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Hexachlorobenzene|1.0|U|ng/L|1.0|5.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|23-NOV-2021|05:13||Kepone|5.2|U|ng/L|5.2|26|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Lambda-Cyhalothrin|0.78|U|ng/L|0.78|3.9|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39480|Methoxychlor|0.31|U|ng/L|0.31|1.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|39755|Mirex|0.72|U|ng/L|0.72|3.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|79191|Permethrin|1.7|U|ng/L|1.7|8.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Prallethrin|2.1|U|ng/L|2.1|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14||Trans-Nonachlor|0.21|U|ng/L|0.21|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290150|FB|FB_11162021|16-NOV-2021|14:25|01-DEC-2021|21:14|81284|Trifluralin|0.21|U|ng/L|0.21|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Acetochlor|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Alachlor|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|82184|Ametryn|0.59|U|ng/L|0.59|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|39033|Atrazine|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Atrazine Desethyl|1.5|U|ng/L|1.5|5.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Azinphos Methyl|2.0|UJ|ng/L|2.0|7.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Azoxystrobin|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Bromacil|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Butylate|0.39|U|ng/L|0.39|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Caffeine|7.4|U|ng/L|7.4|30|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Carbophenothion|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Carfentrazone Ethyl|0.099|U|ng/L|0.099|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Chlorfenapyr|0.17|U|ng/L|0.17|0.69|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|38932|Chlorpyrifos Ethyl|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|38740|Chlorpyrifos Methyl|0.049|U|ng/L|0.049|0.20|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Coumaphos|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Cyanazine|3.2|U|ng/L|3.2|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Cyprodinil|0.099|U|ng/L|0.099|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Demeton|1.5|U|ng/L|1.5|5.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Diazinon|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Difenoconazole|0.59|UJ|ng/L|0.59|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Dimethenamid|0.099|U|ng/L|0.099|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Dimethomorph|0.17|U|ng/L|0.17|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|81888|Disulfoton|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Dithiopyr|0.17|U|ng/L|0.17|0.69|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||EPTC|1.2|U|ng/L|1.2|4.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|39398|Ethion|0.15|U|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|81758|Ethoprop|0.099|U|ng/L|0.099|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Etridiazole|0.15|U|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fenamiphos|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fenbuconazole|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fipronil|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fipronil Desulfinyl|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fipronil Sulfide|0.15|U|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fipronil Sulfone|0.15|U|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fluazifop-P-butyl|0.099|U|ng/L|0.099|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fludioxonil|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Flumioxazin|1.7|U|ng/L|1.7|6.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Flutolanil|0.099|U|ng/L|0.099|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fluxapyroxad|0.099|U|ng/L|0.099|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Fonofos|0.20|U|ng/L|0.20|0.79|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|38815|Hexazinone|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Imazalil|0.74|U|ng/L|0.74|3.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Iprodione|0.59|U|ng/L|0.59|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Loratadine|0.099|UJ|ng/L|0.099|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|39530|Malathion|0.35|U|ng/L|0.35|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Metalaxyl|0.74|U|ng/L|0.74|3.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Metolachlor|0.35|U|ng/L|0.35|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|81408|Metribuzin|3.2|U|ng/L|3.2|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|39610|Mevinphos|1.0|U|ng/L|1.0|4.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Molinate|0.30|U|ng/L|0.30|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Myclobutanil|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Naled|1.5|UJ|ng/L|1.5|5.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Napropamide|0.39|U|ng/L|0.39|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|78064|Norflurazon|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Oxadiazon|0.30|U|ng/L|0.30|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Oxyfluorfen|0.15|U|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Parathion Ethyl|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Parathion Methyl|0.54|U|ng/L|0.54|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Pendimethalin|0.99|U|ng/L|0.99|3.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Phenytoin|3.5|U|ng/L|3.5|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|46313|Phorate|0.52|U|ng/L|0.52|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Prodiamine|0.17|U|ng/L|0.17|0.69|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|39056|Prometon|0.89|U|ng/L|0.89|3.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|39057|Prometryn|0.20|U|ng/L|0.20|0.79|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Pronamide|0.15|U|ng/L|0.15|0.59|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Propanil|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Propargite|1.5|U|ng/L|1.5|5.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Propiconazole|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Pyraflufen Ethyl|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Pyridaben|0.44|U|ng/L|0.44|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Pyriproxyfen|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|39055|Simazine|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Stirophos|0.12|U|ng/L|0.12|0.49|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Sulfentrazone|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Tebuconazole|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23|82088|Terbufos|0.099|U|ng/L|0.099|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Terbuthylazine|0.42|U|ng/L|0.42|1.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Thiobencarb|0.59|U|ng/L|0.59|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-90|2290151|FB|FB_11162021|16-NOV-2021|14:25|22-NOV-2021|19:23||Triadimefon|0.25|U|ng/L|0.25|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|19-NOV-2021|08:00|EPA 8270E|Thomas Baker, Monica Jaeger|MS accuracy for some parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|46570|Hardness|145||mg/L|0.35|1.4|||||SM 2340B|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|916|Calcium|34.0||mg/L|0.075|0.30|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|1045|Iron|390||ug/L|30|120|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|927|Magnesium|14.6||mg/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|937|Potassium|6.4||mg/L|0.30|1.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|929|Sodium|16.8||mg/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|1082|Strontium|1.20E+03||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|1102|Tin|3.0|U|ug/L|3.0|12|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|1152|Titanium|1.3|I|ug/L|0.75|3.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|1087|Vanadium|2.8|I|ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|18:33|1092|Zinc|5.7|I|ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.7 Rev. 4.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|30-NOV-2021|16:03|1105|Aluminum|133||ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1097|Antimony|0.18|I|ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1002|Arsenic|1.13||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1007|Barium|13.6||ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|30-NOV-2021|16:03|1012|Beryllium|0.014|I|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1022|Boron|48.5||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1027|Cadmium|0.029|I|ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1034|Chromium|0.60|I|ug/L|0.40|1.6|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1037|Cobalt|0.170||ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|02-DEC-2021|13:35|1042|Copper|0.89||ug/L|0.40|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1051|Lead|0.20|U|ug/L|0.20|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1055|Manganese|15.0||ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1062|Molybdenum|1.86||ug/L|0.15|0.60|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1067|Nickel|0.84|I|ug/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1147|Selenium|0.21|I|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1077|Silver|0.010|U|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger| RQ-2021-11-15-46|TLH-2021-11-17-92|2290153|Peace Above Thornton|G3SD0182|16-NOV-2021|11:10|23-NOV-2021|22:23|1059|Thallium|0.10|U|ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|18-NOV-2021|10:00|EPA 200.8 Rev. 5.4|Thomas Baker, Monica Jaeger|