REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2022-06-06-49|TLH-2022-06-09-50|2333427|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|19-JUN-2022|02:34||Total Alkalinity|139||mg CaCO3/L|1.0|2.5|||||SM 2320 B-2011|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-50|2333427|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|09-JUN-2022|13:52|76|Turbidity|3.4||NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-50|2333427|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|24-JUN-2022|14:44|951|Fluoride|1.0||mg F/L|0.18|0.50|||||SM 4500-F- C-2011|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-50|2333427|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|14-JUN-2022|14:14|530|TSS|6|IA|mg/L|3.0|10|||||SM 2540 D-2011|Nicole Reistad/Monica Jaeger|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2022-06-06-49|TLH-2022-06-09-50|2333428|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|22-JUN-2022|15:45|610|Ammonia-N|0.064||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-50|2333428|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|27-JUN-2022|13:54|630|NO2NO3-N|0.029||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-50|2333428|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|20-JUN-2022|17:13|665|Total-P|0.034||mg P/L|0.0040|0.010|365.1 (MARCH 1983)|Automated, ascorbic acid|15-JUN-2022|11:23|EPA 365.1 Rev. 2.0|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-50|2333428|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|22-JUN-2022|14:37|625|Kjeldahl Nitrogen|0.67||mg N/L|0.16|0.40|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|21-JUN-2022|16:37|EPA 351.2 Rev. 2.0|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-50|2333428|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|07:25|680|Organic Carbon|8.7||mg C/L|2.0|4.0|||||SM 5310 B-2011|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Acetochlor|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Alachlor|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|82184|Ametryn|0.61|U|ng/L|0.61|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|39033|Atrazine|0.66|I|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Atrazine Desethyl|1.5|U|ng/L|1.5|6.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Azinphos Methyl|2.0|U|ng/L|2.0|8.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Azoxystrobin|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Bromacil|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Butylate|0.41|U|ng/L|0.41|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Caffeine|7.6|U|ng/L|7.6|30|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Carbophenothion|0.20|U|ng/L|0.20|0.81|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Carfentrazone Ethyl|0.10|U|ng/L|0.10|0.41|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Chlorfenapyr|0.18|U|ng/L|0.18|0.71|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|38932|Chlorpyrifos Ethyl|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|38740|Chlorpyrifos Methyl|0.051|U|ng/L|0.051|0.20|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Coumaphos|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Cyanazine|3.3|U|ng/L|3.3|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Cyprodinil|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Demeton|1.5|U|ng/L|1.5|6.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Diazinon|0.13|U|ng/L|0.13|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Difenoconazole|0.61|U|ng/L|0.61|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Dimethenamid|0.10|U|ng/L|0.10|0.41|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Dimethomorph|0.18|U|ng/L|0.18|1.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|81888|Disulfoton|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Dithiopyr|0.18|U|ng/L|0.18|0.71|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||EPTC|1.3|U|ng/L|1.3|5.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|39398|Ethion|0.15|U|ng/L|0.15|0.61|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|81758|Ethoprop|0.10|U|ng/L|0.10|0.41|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Etridiazole|0.15|UJ|ng/L|0.15|0.61|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fenamiphos|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fenbuconazole|0.13|U|ng/L|0.13|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fipronil|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fipronil Desulfinyl|0.13|U|ng/L|0.13|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fipronil Sulfide|0.15|U|ng/L|0.15|0.61|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fipronil Sulfone|0.15|U|ng/L|0.15|0.61|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fluazifop-P-butyl|0.10|U|ng/L|0.10|0.41|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fludioxonil|0.13|U|ng/L|0.13|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Flumioxazin|1.8|U|ng/L|1.8|7.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Flutolanil|0.10|U|ng/L|0.10|0.41|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fluxapyroxad|0.10|U|ng/L|0.10|0.41|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Fonofos|0.20|U|ng/L|0.20|0.81|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|38815|Hexazinone|1.1|I|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Imazalil|0.76|U|ng/L|0.76|3.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Iprodione|0.61|U|ng/L|0.61|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Loratadine|0.10|U|ng/L|0.10|0.41|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|39530|Malathion|0.35|U|ng/L|0.35|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Metalaxyl|0.76|U|ng/L|0.76|3.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Metolachlor|0.35|U|ng/L|0.35|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|81408|Metribuzin|2.5|U|ng/L|2.5|10|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|39610|Mevinphos|1.1|U|ng/L|1.1|4.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Molinate|0.30|U|ng/L|0.30|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Myclobutanil|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Naled|1.5|U|ng/L|1.5|6.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Napropamide|0.41|U|ng/L|0.41|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|78064|Norflurazon|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Oxadiazon|0.30|U|ng/L|0.30|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Oxyfluorfen|0.15|U|ng/L|0.15|0.61|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Parathion Ethyl|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Parathion Methyl|0.56|U|ng/L|0.56|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Pendimethalin|1.0|U|ng/L|1.0|4.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Phenytoin|3.5|U|ng/L|3.5|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|46313|Phorate|0.53|U|ng/L|0.53|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Prodiamine|0.18|U|ng/L|0.18|0.71|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|39056|Prometon|0.91|U|ng/L|0.91|3.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|39057|Prometryn|0.20|U|ng/L|0.20|0.81|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Pronamide|0.15|U|ng/L|0.15|0.61|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Propanil|0.13|U|ng/L|0.13|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Propargite|1.5|U|ng/L|1.5|6.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Propiconazole|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Pyraflufen Ethyl|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Pyridaben|0.46|U|ng/L|0.46|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Pyriproxyfen|0.13|U|ng/L|0.13|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|39055|Simazine|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Stirophos|0.13|U|ng/L|0.13|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Sulfentrazone|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Tebuconazole|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00|82088|Terbufos|0.10|U|ng/L|0.10|0.41|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Terbuthylazine|0.43|U|ng/L|0.43|1.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Thiobencarb|0.61|U|ng/L|0.61|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|16:00||Triadimefon|0.25|U|ng/L|0.25|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|20:11||2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (EHTBB)|12|U|ng/L|12|36|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|20:11||Avobenzone|100|U|ng/L|100|300|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|20:11||Octinoxate|20|U|ng/L|20|61|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|20:11||Oxybenzone|10|U|ng/L|10|30|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|20:11||PBDE-47|4.1|U|ng/L|4.1|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|20:11||PBDE-99|5.1|U|ng/L|5.1|15|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333434|ENRE10 Lopez River|G5SD0092|08-JUN-2022|10:25|17-JUN-2022|20:11||Tri-o-cresyl Phosphate|6.1|U|ng/L|6.1|18|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Acetochlor|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Alachlor|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|82184|Ametryn|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|39033|Atrazine|0.98||ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Atrazine Desethyl|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Azinphos Methyl|1.9|U|ng/L|1.9|7.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Azoxystrobin|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Bromacil|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Butylate|0.39|U|ng/L|0.39|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Caffeine|7.2|U|ng/L|7.2|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Carbophenothion|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Carfentrazone Ethyl|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Chlorfenapyr|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|38932|Chlorpyrifos Ethyl|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|38740|Chlorpyrifos Methyl|0.048|U|ng/L|0.048|0.19|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Coumaphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Cyanazine|3.1|U|ng/L|3.1|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Cyprodinil|0.097|U|ng/L|0.097|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Demeton|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Diazinon|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Difenoconazole|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Dimethenamid|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Dimethomorph|0.17|U|ng/L|0.17|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|81888|Disulfoton|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Dithiopyr|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||EPTC|1.2|U|ng/L|1.2|4.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|39398|Ethion|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|81758|Ethoprop|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Etridiazole|0.14|UJ|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fenamiphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fenbuconazole|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fipronil|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fipronil Desulfinyl|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fipronil Sulfide|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fipronil Sulfone|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fluazifop-P-butyl|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fludioxonil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Flumioxazin|1.7|U|ng/L|1.7|6.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Flutolanil|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fluxapyroxad|0.19|I|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Fonofos|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|38815|Hexazinone|62||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Imazalil|0.72|U|ng/L|0.72|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Iprodione|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Loratadine|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|39530|Malathion|0.34|U|ng/L|0.34|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Metalaxyl|0.72|U|ng/L|0.72|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Metolachlor|0.79|I|ng/L|0.34|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|81408|Metribuzin|2.4|U|ng/L|2.4|9.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|39610|Mevinphos|1.0|U|ng/L|1.0|4.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Molinate|0.29|U|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Myclobutanil|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Naled|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Napropamide|0.39|U|ng/L|0.39|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|78064|Norflurazon|0.75|I|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Oxadiazon|2.6||ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Oxyfluorfen|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Parathion Ethyl|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Parathion Methyl|0.53|U|ng/L|0.53|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Pendimethalin|0.97|U|ng/L|0.97|3.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Phenytoin|3.4|U|ng/L|3.4|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|46313|Phorate|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Prodiamine|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|39056|Prometon|0.87|U|ng/L|0.87|3.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|39057|Prometryn|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Pronamide|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Propanil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Propargite|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Propiconazole|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Pyraflufen Ethyl|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Pyridaben|0.43|U|ng/L|0.43|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Pyriproxyfen|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|39055|Simazine|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Stirophos|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Sulfentrazone|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Tebuconazole|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27|82088|Terbufos|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Terbuthylazine|0.41|U|ng/L|0.41|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Thiobencarb|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|16:27||Triadimefon|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|20:31||2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (EHTBB)|12|U|ng/L|12|35|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|20:31||Avobenzone|97|U|ng/L|97|290|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|20:31||Octinoxate|19|U|ng/L|19|58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|20:31||Oxybenzone|9.7|U|ng/L|9.7|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|20:31||PBDE-47|3.9|U|ng/L|3.9|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|20:31||PBDE-99|4.8|U|ng/L|4.8|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333435|BarronRiverCanalAtUS41|G1SD0125|08-JUN-2022|11:45|17-JUN-2022|20:31||Tri-o-cresyl Phosphate|5.8|U|ng/L|5.8|17|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Acetochlor|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Alachlor|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|82184|Ametryn|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|39033|Atrazine|1.1||ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Atrazine Desethyl|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Azinphos Methyl|1.9|U|ng/L|1.9|7.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Azoxystrobin|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Bromacil|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Butylate|0.38|U|ng/L|0.38|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Caffeine|7.2|U|ng/L|7.2|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Carbophenothion|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Carfentrazone Ethyl|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Chlorfenapyr|0.17|U|ng/L|0.17|0.67|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|38932|Chlorpyrifos Ethyl|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|38740|Chlorpyrifos Methyl|0.048|U|ng/L|0.048|0.19|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Coumaphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Cyanazine|3.1|U|ng/L|3.1|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Cyprodinil|0.096|U|ng/L|0.096|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Demeton|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Diazinon|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Difenoconazole|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Dimethenamid|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Dimethomorph|0.17|U|ng/L|0.17|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|81888|Disulfoton|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Dithiopyr|0.17|U|ng/L|0.17|0.67|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||EPTC|1.2|U|ng/L|1.2|4.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|39398|Ethion|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|81758|Ethoprop|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Etridiazole|0.14|UJ|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fenamiphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fenbuconazole|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fipronil|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fipronil Desulfinyl|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fipronil Sulfide|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fipronil Sulfone|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fluazifop-P-butyl|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fludioxonil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Flumioxazin|1.7|U|ng/L|1.7|6.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Flutolanil|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fluxapyroxad|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Fonofos|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|38815|Hexazinone|1.2|I|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Imazalil|0.72|U|ng/L|0.72|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Iprodione|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Loratadine|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|39530|Malathion|0.34|U|ng/L|0.34|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Metalaxyl|0.72|U|ng/L|0.72|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Metolachlor|0.46|I|ng/L|0.34|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|81408|Metribuzin|2.4|U|ng/L|2.4|9.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|39610|Mevinphos|1.0|U|ng/L|1.0|4.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Molinate|0.29|U|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Myclobutanil|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Naled|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Napropamide|0.38|U|ng/L|0.38|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|78064|Norflurazon|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Oxadiazon|1.8||ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Oxyfluorfen|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Parathion Ethyl|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Parathion Methyl|0.53|U|ng/L|0.53|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Pendimethalin|0.96|U|ng/L|0.96|3.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Phenytoin|3.4|U|ng/L|3.4|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|46313|Phorate|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Prodiamine|0.17|U|ng/L|0.17|0.67|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|39056|Prometon|0.86|U|ng/L|0.86|3.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|39057|Prometryn|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Pronamide|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Propanil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Propargite|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Propiconazole|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Pyraflufen Ethyl|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Pyridaben|0.43|U|ng/L|0.43|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Pyriproxyfen|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|39055|Simazine|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Stirophos|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Sulfentrazone|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Tebuconazole|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54|82088|Terbufos|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Terbuthylazine|0.41|U|ng/L|0.41|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Thiobencarb|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|16:54||Triadimefon|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|20:50||2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (EHTBB)|12|U|ng/L|12|35|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|20:50||Avobenzone|96|U|ng/L|96|290|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|20:50||Octinoxate|19|U|ng/L|19|58|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|20:50||Oxybenzone|9.6|U|ng/L|9.6|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|20:50||PBDE-47|3.8|U|ng/L|3.8|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|20:50||PBDE-99|4.8|U|ng/L|4.8|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger| RQ-2022-06-06-49|TLH-2022-06-09-53|2333436|Canal At PlantationPkwy|G1SD0126|08-JUN-2022|11:15|17-JUN-2022|20:50||Tri-o-cresyl Phosphate|5.8|U|ng/L|5.8|17|3510C (TQ)|Separatory funnel liquid-liquid extraction|14-JUN-2022|08:00|EPA 8270E|Nicole Reistad/Monica Jaeger|