REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2022-06-13-32|TLH-2022-06-14-23|2334143|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|24-JUN-2022|09:23||Total Alkalinity|126|A|mg CaCO3/L|1.0|2.5|||||SM 2320 B-2011|Monica Jaeger, William Mullen| RQ-2022-06-13-32|TLH-2022-06-14-23|2334143|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|14-JUN-2022|16:15|76|Turbidity|2.2||NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Monica Jaeger, William Mullen| RQ-2022-06-13-32|TLH-2022-06-14-23|2334143|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|24-JUN-2022|08:09|951|Fluoride|0.97||mg F/L|0.18|0.50|||||SM 4500-F- C-2011|Monica Jaeger, William Mullen| RQ-2022-06-13-32|TLH-2022-06-14-23|2334143|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|17-JUN-2022|14:36|530|TSS|6|IA|mg/L|3.0|10|||||SM 2540 D-2011|Monica Jaeger, William Mullen|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2022-06-13-32|TLH-2022-06-14-23|2334144|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|23-JUN-2022|16:11|610|Ammonia-N|0.025||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Monica Jaeger, William Mullen| RQ-2022-06-13-32|TLH-2022-06-14-23|2334144|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|27-JUN-2022|14:28|630|NO2NO3-N|0.037||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Monica Jaeger, William Mullen| RQ-2022-06-13-32|TLH-2022-06-14-23|2334144|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|23-JUN-2022|11:38|665|Total-P|0.11||mg P/L|0.010|0.10|365.1 (MARCH 1983)|Automated, ascorbic acid|22-JUN-2022|17:36|EPA 365.1 Rev. 2.0|Monica Jaeger, William Mullen| RQ-2022-06-13-32|TLH-2022-06-14-23|2334144|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|23-JUN-2022|11:43|625|Kjeldahl Nitrogen|0.65||mg N/L|0.16|0.40|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|22-JUN-2022|15:49|EPA 351.2 Rev. 2.0|Monica Jaeger, William Mullen| RQ-2022-06-13-32|TLH-2022-06-14-23|2334144|Hatchett Creek Tidal 2|G3SD0192|13-JUN-2022|10:00|18-JUN-2022|06:48|680|Organic Carbon|6.1||mg C/L|2.0|4.0|||||SM 5310 B-2011|Monica Jaeger, William Mullen| RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Acetochlor|0.24|U|ng/L|0.24|0.94|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Alachlor|0.24|U|ng/L|0.24|0.94|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|82184|Ametryn|0.56|U|ng/L|0.56|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|25-JUN-2022|22:31|39033|Atrazine|77||ng/L|2.4|9.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Atrazine Desethyl|9.3||ng/L|1.4|5.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Azinphos Methyl|1.9|U|ng/L|1.9|7.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Azoxystrobin|1.7|I|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Bromacil|0.47|U|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Butylate|0.38|U|ng/L|0.38|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Caffeine|21|I|ng/L|7.1|28|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Carbophenothion|0.19|U|ng/L|0.19|0.75|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Carfentrazone Ethyl|0.094|U|ng/L|0.094|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Chlorfenapyr|0.26|I|ng/L|0.16|0.66|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|38932|Chlorpyrifos Ethyl|0.24|U|ng/L|0.24|0.94|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|38740|Chlorpyrifos Methyl|0.047|U|ng/L|0.047|0.19|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Coumaphos|0.47|U|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Cyanazine|3.1|U|ng/L|3.1|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Cyprodinil|0.094|U|ng/L|0.094|0.47|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Demeton|1.4|U|ng/L|1.4|5.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Diazinon|0.12|U|ng/L|0.12|0.47|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Difenoconazole|0.56|U|ng/L|0.56|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Dimethenamid|0.094|U|ng/L|0.094|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Dimethomorph|0.16|U|ng/L|0.16|0.99|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|81888|Disulfoton|0.47|U|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Dithiopyr|0.16|U|ng/L|0.16|0.66|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||EPTC|1.2|U|ng/L|1.2|4.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|39398|Ethion|0.14|U|ng/L|0.14|0.56|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|81758|Ethoprop|0.094|U|ng/L|0.094|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Etridiazole|0.14|U|ng/L|0.14|0.56|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fenamiphos|0.47|U|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fenbuconazole|0.12|U|ng/L|0.12|0.47|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fipronil|1.1||ng/L|0.24|0.94|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fipronil Desulfinyl|2.2||ng/L|0.12|0.47|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fipronil Sulfide|0.94||ng/L|0.14|0.56|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fipronil Sulfone|2.4||ng/L|0.14|0.56|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fluazifop-P-butyl|0.094|U|ng/L|0.094|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fludioxonil|0.12|U|ng/L|0.12|0.47|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Flumioxazin|1.6|U|ng/L|1.6|6.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Flutolanil|0.094|U|ng/L|0.094|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fluxapyroxad|0.73||ng/L|0.094|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Fonofos|0.19|U|ng/L|0.19|0.75|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|38815|Hexazinone|0.60|I|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Imazalil|0.71|U|ng/L|0.71|2.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Iprodione|0.56|U|ng/L|0.56|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Loratadine|0.094|U|ng/L|0.094|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|39530|Malathion|0.33|U|ng/L|0.33|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Metalaxyl|0.71|U|ng/L|0.71|2.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Metolachlor|0.33|U|ng/L|0.33|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|81408|Metribuzin|2.4|U|ng/L|2.4|9.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|39610|Mevinphos|0.99|U|ng/L|0.99|4.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Molinate|0.28|U|ng/L|0.28|1.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Myclobutanil|0.24|U|ng/L|0.24|0.94|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Naled|1.4|UJ|ng/L|1.4|5.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Napropamide|0.38|U|ng/L|0.38|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|78064|Norflurazon|0.47|U|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Oxadiazon|1.2||ng/L|0.28|1.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Oxyfluorfen|0.14|U|ng/L|0.14|0.56|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Parathion Ethyl|0.24|U|ng/L|0.24|0.94|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Parathion Methyl|0.52|U|ng/L|0.52|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Pendimethalin|0.94|U|ng/L|0.94|3.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Phenytoin|3.3|U|ng/L|3.3|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|46313|Phorate|0.49|U|ng/L|0.49|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Prodiamine|0.16|U|ng/L|0.16|0.66|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|39056|Prometon|0.85|U|ng/L|0.85|3.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|39057|Prometryn|0.19|U|ng/L|0.19|0.75|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Pronamide|0.14|U|ng/L|0.14|0.56|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Propanil|0.12|U|ng/L|0.12|0.47|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Propargite|1.4|U|ng/L|1.4|5.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Propiconazole|0.92|I|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Pyraflufen Ethyl|0.24|U|ng/L|0.24|0.94|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Pyridaben|0.42|U|ng/L|0.42|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Pyriproxyfen|0.12|U|ng/L|0.12|0.47|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|39055|Simazine|0.47|U|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Stirophos|0.12|U|ng/L|0.12|0.47|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Sulfentrazone|6.7||ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Tebuconazole|1.1|I|ng/L|0.47|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40|82088|Terbufos|0.094|U|ng/L|0.094|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Terbuthylazine|0.40|U|ng/L|0.40|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Thiobencarb|0.56|U|ng/L|0.56|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|24-JUN-2022|17:40||Triadimefon|0.24|U|ng/L|0.24|0.94|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|MS accuracy for multiple parameters not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|28-JUN-2022|16:06||2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (EHTBB)|11|U|ng/L|11|34|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|28-JUN-2022|16:06||Avobenzone|94|U|ng/L|94|280|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|28-JUN-2022|16:06||Octinoxate|65|J|ng/L|19|56|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|28-JUN-2022|16:06||Oxybenzone|9.4|U|ng/L|9.4|28|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|28-JUN-2022|16:06||PBDE-47|3.8|U|ng/L|3.8|11|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|28-JUN-2022|16:06||PBDE-99|4.7|U|ng/L|4.7|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-06-13-32|TLH-2022-06-14-30|2334155|HatchettCreek@GroveStN|G3SD0194|13-JUN-2022|10:45|28-JUN-2022|16:06||Tri-o-cresyl Phosphate|5.6|U|ng/L|5.6|17|3510C (TQ)|Separatory funnel liquid-liquid extraction|20-JUN-2022|08:00|EPA 8270E|Monica Jaeger, William Mullen|Refer to the Lab Analysis Report for an explanation of QC Codes.