REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2022-09-26-38|TLH-2022-09-27-60|2359597|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|06-OCT-2022|04:08||Total Alkalinity|59||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Thomas Baker, Monica Jaeger|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2022-09-26-38|TLH-2022-09-27-60|2359597|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|27-SEP-2022|15:20|76|Turbidity|4.6|A|NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359597|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|05:49|940|Chloride|24||mg Cl/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359597|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|27-SEP-2022|15:56|80|Color (true)|360||PCU|12|30|||||DEP SOP: NU-094-1|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359597|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|06-OCT-2022|04:08|951|Fluoride|0.12||mg F/L|0.035|0.10|||||SM 4500-F- C-2011|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359597|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|05:49|945|Sulfate|20||mg SO4/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359597|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|16:11|70300|TDS|222|A|mg/L|15|25|||||SM 2540 C-2015|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359597|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|16:11|530|TSS|4|IA|mg/L|2.0|10|||||SM 2540 D-2015|Thomas Baker, Monica Jaeger|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2022-09-26-38|TLH-2022-09-27-60|2359598|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|06-OCT-2022|13:49|610|Ammonia-N|2.7||mg N/L|0.20|0.50|||||EPA 350.1 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359598|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|05-OCT-2022|11:00|630|NO2NO3-N|1.7||mg N/L|0.040|0.10|||||EPA 353.2 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359598|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|03-OCT-2022|11:53|665|Total-P|1.8||mg P/L|0.050|0.25|365.1 (MARCH 1983)|Automated, ascorbic acid|30-SEP-2022|12:23|EPA 365.1 Rev. 2.0|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-60|2359598|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|07-OCT-2022|12:37|625|Kjeldahl Nitrogen|5.4||mg N/L|0.40|1.0|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|29-SEP-2022|11:16|EPA 351.2 Rev. 2.0|Thomas Baker, Monica Jaeger|Batch matrix spike recoveries are unavailable because of high analyte concentration in the QC sample. RQ-2022-09-26-38|TLH-2022-09-27-60|2359598|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|05-OCT-2022|03:39|680|Organic Carbon|35||mg C/L|0.50|1.0|||||SM 5310 B-2011|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|11:43||AMPA|0.55||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|30-SEP-2022|09:00|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|17:34||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|30-SEP-2022|09:00|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|11:43||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|30-SEP-2022|09:00|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|11:43||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|30-SEP-2022|09:00|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|11:43||Glyphosate|0.59||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|30-SEP-2022|09:00|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|17:34||Sucralose|0.073||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|30-SEP-2022|09:00|EPA 8321B|Thomas Baker, Monica Jaeger| RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03|39730|2,4-D|0.013||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Bentazon|0.0060||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Clothianidin|0.11||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Diuron|0.0046|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Fenuron|0.032|U|ug/L|0.032|0.064|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Ibuprofen|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Imazapyr|0.0074|I|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Imidacloprid|0.16||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03|39760|Silvex|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Thiamethoxam|0.63||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample. RQ-2022-09-26-38|TLH-2022-09-27-64|2359602|BonnetCreekAtoldBmbngRd|G4SD0211|26-SEP-2022|12:15|30-SEP-2022|21:03||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|30-SEP-2022|09:30|EPA 8321B|Thomas Baker, Monica Jaeger|MS accuracy for bentazon could not be assessed due to a high concentration of parameters in the spiked sample.