REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2022-10-31-36|TLH-2022-11-04-01|2367527|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|08-NOV-2022|23:06||Total Alkalinity|120||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367527|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|04-NOV-2022|13:49|76|Turbidity|2.1||NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367527|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|08-NOV-2022|20:45|951|Fluoride|1.0||mg F/L|0.12|0.50|||||SM 4500-F- C-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367527|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|16:35|530|TSS|3|IA|mg/L|3.0|10|||||SM 2540 D-2015|Nicole Reistad, William Mullen|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2022-10-31-36|TLH-2022-11-04-01|2367528|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|08-NOV-2022|12:55|610|Ammonia-N|0.021||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367528|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|15-NOV-2022|11:59|630|NO2NO3-N|0.032||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367528|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|14-NOV-2022|15:55|665|Total-P|0.056||mg P/L|0.0040|0.010|365.1 (MARCH 1983)|Automated, ascorbic acid|10-NOV-2022|11:40|EPA 365.1 Rev. 2.0|Nicole Reistad, William Mullen|Total-P: Batch matrix spike recoveries are unavailable because of high analyte concentration in the QC sample. RQ-2022-10-31-36|TLH-2022-11-04-01|2367528|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|11:19|625|Kjeldahl Nitrogen|0.53||mg N/L|0.16|0.40|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|07-NOV-2022|11:40|EPA 351.2 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367528|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|18-NOV-2022|06:07|680|Organic Carbon|6.3||mg C/L|2.0|4.0|||||SM 5310 B-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367529|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|08-NOV-2022|21:30||Total Alkalinity|261||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367529|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|04-NOV-2022|13:50|76|Turbidity|3.7||NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367529|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|08-NOV-2022|19:35|951|Fluoride|0.48||mg F/L|0.050|0.20|||||SM 4500-F- C-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367529|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|09-NOV-2022|16:35|530|TSS|6|I|mg/L|2.0|10|||||SM 2540 D-2015|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367530|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|17-NOV-2022|12:32|610|Ammonia-N|0.008||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367530|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|15-NOV-2022|12:00|630|NO2NO3-N|0.004|U|mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367530|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|14-NOV-2022|15:56|665|Total-P|0.097||mg P/L|0.0040|0.010|365.1 (MARCH 1983)|Automated, ascorbic acid|10-NOV-2022|11:40|EPA 365.1 Rev. 2.0|Nicole Reistad, William Mullen|Total-P: Batch matrix spike recoveries are unavailable because of high analyte concentration in the QC sample. RQ-2022-10-31-36|TLH-2022-11-04-01|2367530|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|09-NOV-2022|11:24|625|Kjeldahl Nitrogen|1.2||mg N/L|0.16|0.40|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|07-NOV-2022|11:40|EPA 351.2 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367530|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|17-NOV-2022|22:21|680|Organic Carbon|15||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367531|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|10-NOV-2022|11:56||Total Alkalinity|202||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367531|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|04-NOV-2022|13:51|76|Turbidity|1.3||NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367531|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|11-NOV-2022|03:04|940|Chloride|50||mg Cl/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367531|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|04-NOV-2022|14:24|80|Color (true)|62||PCU|2.5|6.0|||||DEP SOP: NU-094-1|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367531|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|30-NOV-2022|07:05|951|Fluoride|0.12||mg F/L|0.025|0.10|||||SM 4500-F- C-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367531|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|11-NOV-2022|03:04|945|Sulfate|12||mg SO4/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367531|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|09-NOV-2022|16:35|70300|TDS|327||mg/L|15|25|||||SM 2540 C-2015|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367531|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|09-NOV-2022|16:35|530|TSS|2|I|mg/L|2.0|10|||||SM 2540 D-2015|Nicole Reistad, William Mullen|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2022-10-31-36|TLH-2022-11-04-01|2367532|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|16-NOV-2022|14:05|610|Ammonia-N|0.094||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367532|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|09-NOV-2022|12:30|630|NO2NO3-N|0.062||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367532|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|14-NOV-2022|11:02|665|Total-P|0.053||mg P/L|0.010|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|10-NOV-2022|11:40|EPA 365.1 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367532|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|16-NOV-2022|12:34|625|Kjeldahl Nitrogen|0.99||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|14-NOV-2022|12:45|EPA 351.2 Rev. 2.0|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-01|2367532|Oak Creek @ Kentucky St|G1SD0116|03-NOV-2022|11:30|18-NOV-2022|11:49|680|Organic Carbon|14||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Acetochlor|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Alachlor|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|82184|Ametryn|1.6|I|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|39033|Atrazine|6.7||ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Atrazine Desethyl|3.1|I|ng/L|1.5|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Azinphos Methyl|1.9|U|ng/L|1.9|7.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Azoxystrobin|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Bromacil|2.0||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Butylate|0.39|U|ng/L|0.39|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Caffeine|9.7|I|ng/L|7.3|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Carbophenothion|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Carfentrazone Ethyl|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Chlorfenapyr|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|38932|Chlorpyrifos Ethyl|0.24|UJ|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|38740|Chlorpyrifos Methyl|0.048|U|ng/L|0.048|0.19|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Coumaphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Cyanazine|3.1|U|ng/L|3.1|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Cyprodinil|0.097|U|ng/L|0.097|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Demeton|1.5|U|ng/L|1.5|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Diazinon|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Difenoconazole|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Dimethenamid|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Dimethomorph|0.17|U|ng/L|0.17|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|81888|Disulfoton|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Dithiopyr|0.61|U|ng/L|0.61|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||EPTC|1.2|U|ng/L|1.2|4.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|39398|Ethion|0.15|U|ng/L|0.15|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|81758|Ethoprop|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Etridiazole|0.15|U|ng/L|0.15|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fenamiphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fenbuconazole|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fipronil|0.24|UJ|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fipronil Desulfinyl|0.14|I|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fipronil Sulfide|0.15|U|ng/L|0.15|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fipronil Sulfone|0.21|I|ng/L|0.15|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fluazifop-P-butyl|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fludioxonil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Flumioxazin|4.4|U|ng/L|4.4|17|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Flutolanil|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fluxapyroxad|0.47||ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Fonofos|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|38815|Hexazinone|10||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Imazalil|0.73|U|ng/L|0.73|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Iprodione|0.58|UJ|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Loratadine|0.34|U|ng/L|0.34|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|39530|Malathion|0.69|I|ng/L|0.34|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Metalaxyl|0.97|I|ng/L|0.73|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Metolachlor|2.1||ng/L|0.34|1.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|81408|Metribuzin|1.5|U|ng/L|1.5|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|39610|Mevinphos|1.0|U|ng/L|1.0|4.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Molinate|0.29|U|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Myclobutanil|0.34|I|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Naled|1.5|U|ng/L|1.5|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Napropamide|0.39|U|ng/L|0.39|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|78064|Norflurazon|12||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Oxadiazon|0.94|I|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Oxyfluorfen|0.15|U|ng/L|0.15|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Parathion Ethyl|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Parathion Methyl|0.53|U|ng/L|0.53|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Pendimethalin|0.97|U|ng/L|0.97|3.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Phenytoin|3.4|UJ|ng/L|3.4|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|46313|Phorate|0.51|U|ng/L|0.51|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Prodiamine|0.17|U|ng/L|0.17|0.68|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|39056|Prometon|0.87|U|ng/L|0.87|3.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|39057|Prometryn|0.19|UJ|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Pronamide|0.15|U|ng/L|0.15|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Propanil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Propargite|1.5|U|ng/L|1.5|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Propiconazole|1.1|I|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Pyraflufen Ethyl|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Pyridaben|0.44|U|ng/L|0.44|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Pyriproxyfen|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|39055|Simazine|1.3|I|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Stirophos|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Sulfentrazone|1.3|I|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Tebuconazole|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56|82088|Terbufos|0.097|U|ng/L|0.097|0.39|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Terbuthylazine|0.41|U|ng/L|0.41|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Thiobencarb|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|09-NOV-2022|18:56||Triadimefon|0.24|U|ng/L|0.24|0.97|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|10-NOV-2022|16:09||2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (EHTBB)|12|U|ng/L|12|35|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|10-NOV-2022|16:09||Avobenzone|97|U|ng/L|97|290|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|10-NOV-2022|16:09||Dechlorane Plus|29|U|ng/L|29|87|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|10-NOV-2022|16:09||Octinoxate|19|U|ng/L|19|58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|10-NOV-2022|16:09||Oxybenzone|9.7|U|ng/L|9.7|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|10-NOV-2022|16:09||PBDE-47|3.9|U|ng/L|3.9|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|10-NOV-2022|16:09||PBDE-99|4.8|U|ng/L|4.8|15|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367538|Punta Rassa Cove|G2SD0047|03-NOV-2022|09:10|10-NOV-2022|16:09||Tri-o-cresyl Phosphate|5.8|U|ng/L|5.8|17|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Acetochlor|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Alachlor|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|82184|Ametryn|2.3||ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|39033|Atrazine|7.9||ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Atrazine Desethyl|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Azinphos Methyl|1.9|U|ng/L|1.9|7.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Azoxystrobin|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Bromacil|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Butylate|0.38|U|ng/L|0.38|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Caffeine|15|I|ng/L|7.2|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Carbophenothion|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Carfentrazone Ethyl|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Chlorfenapyr|0.17|U|ng/L|0.17|0.67|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|38932|Chlorpyrifos Ethyl|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|38740|Chlorpyrifos Methyl|0.048|U|ng/L|0.048|0.19|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Coumaphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Cyanazine|3.1|U|ng/L|3.1|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Cyprodinil|0.096|U|ng/L|0.096|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Demeton|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Diazinon|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Difenoconazole|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Dimethenamid|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Dimethomorph|0.17|U|ng/L|0.17|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|81888|Disulfoton|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Dithiopyr|1.8|I|ng/L|0.60|2.4|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||EPTC|1.2|U|ng/L|1.2|4.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|39398|Ethion|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|81758|Ethoprop|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Etridiazole|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fenamiphos|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fenbuconazole|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fipronil|0.56|I|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fipronil Desulfinyl|1.1||ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fipronil Sulfide|0.85||ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fipronil Sulfone|2.7||ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fluazifop-P-butyl|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fludioxonil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Flumioxazin|4.3|U|ng/L|4.3|17|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Flutolanil|2.2||ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fluxapyroxad|2.7||ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Fonofos|0.19|U|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|38815|Hexazinone|2.0||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Imazalil|0.72|U|ng/L|0.72|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Iprodione|0.58|UJ|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Loratadine|0.34|U|ng/L|0.34|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|39530|Malathion|7.6||ng/L|0.34|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Metalaxyl|0.72|U|ng/L|0.72|2.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Metolachlor|0.34|U|ng/L|0.34|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|81408|Metribuzin|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|39610|Mevinphos|1.0|U|ng/L|1.0|4.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Molinate|0.29|U|ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Myclobutanil|4.0||ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Naled|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Napropamide|0.38|U|ng/L|0.38|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|78064|Norflurazon|0.84|I|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Oxadiazon|11||ng/L|0.29|1.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Oxyfluorfen|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Parathion Ethyl|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Parathion Methyl|0.53|U|ng/L|0.53|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Pendimethalin|0.96|U|ng/L|0.96|3.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Phenytoin|3.4|U|ng/L|3.4|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|46313|Phorate|0.50|U|ng/L|0.50|2.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Prodiamine|0.17|U|ng/L|0.17|0.67|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|39056|Prometon|0.86|U|ng/L|0.86|3.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|39057|Prometryn|0.19|UJ|ng/L|0.19|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Pronamide|0.14|U|ng/L|0.14|0.58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Propanil|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Propargite|1.4|U|ng/L|1.4|5.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Propiconazole|2.6||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Pyraflufen Ethyl|0.24|U|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Pyridaben|0.43|U|ng/L|0.43|2.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Pyriproxyfen|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|39055|Simazine|0.48|U|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Stirophos|0.12|U|ng/L|0.12|0.48|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Sulfentrazone|48||ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Tebuconazole|1.9|I|ng/L|0.48|1.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03|82088|Terbufos|0.096|U|ng/L|0.096|0.38|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Terbuthylazine|0.41|U|ng/L|0.41|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Thiobencarb|0.58|U|ng/L|0.58|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|00:03||Triadimefon|0.32|I|ng/L|0.24|0.96|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|MS accuracy for atrazine and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|16:29||2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (EHTBB)|12|U|ng/L|12|35|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|16:29||Avobenzone|96|U|ng/L|96|290|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|16:29||Dechlorane Plus|29|U|ng/L|29|86|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|16:29||Octinoxate|19|U|ng/L|19|58|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|16:29||Oxybenzone|9.6|U|ng/L|9.6|29|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|16:29||PBDE-47|3.8|U|ng/L|3.8|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|16:29||PBDE-99|4.8|U|ng/L|4.8|14|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen| RQ-2022-10-31-36|TLH-2022-11-04-04|2367539|HendryCreekHouse1Upstream|G1SD0118|03-NOV-2022|10:20|10-NOV-2022|16:29||Tri-o-cresyl Phosphate|5.8|U|ng/L|5.8|17|3510C (TQ)|Separatory funnel liquid-liquid extraction|08-NOV-2022|08:30|EPA 8270E|Nicole Reistad, William Mullen|