REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|24-MAY-2023|19:44||AMPA|10|U|ug/L|10|40|LC-FILTER|Filtration of samples prior to analysis|24-MAY-2023|12:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|Some MDLs are elevated due to required dilution of sample matrix. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|25-MAY-2023|02:42||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|24-MAY-2023|12:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|Some MDLs are elevated due to required dilution of sample matrix. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|24-MAY-2023|14:56||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|24-MAY-2023|12:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|Some MDLs are elevated due to required dilution of sample matrix. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|24-MAY-2023|19:44||Glufosinate|10|U|ug/L|10|40|LC-FILTER|Filtration of samples prior to analysis|24-MAY-2023|12:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|Some MDLs are elevated due to required dilution of sample matrix. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|24-MAY-2023|19:44||Glyphosate|10|U|ug/L|10|40|LC-FILTER|Filtration of samples prior to analysis|24-MAY-2023|12:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|Some MDLs are elevated due to required dilution of sample matrix. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|25-MAY-2023|02:42||Sucralose|0.060||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|24-MAY-2023|12:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|Some MDLs are elevated due to required dilution of sample matrix. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28|39730|2,4-D|0.0041|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Bentazon|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Fenuron|0.032|U|ug/L|0.032|0.13|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Ibuprofen|0.080|U|ug/L|0.080|0.32|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Imazapyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Imidacloprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||MCPP|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28|39760|Silvex|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-31|2411822|CANAL AT PLANTATIONPKWY|G1SD0126|22-MAY-2023|09:25|26-MAY-2023|14:28||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|25-MAY-2023|09:00|EPA 8321B|Nicole Reistad, Monica Jaeg er|MS accuracy for some analytes could not be assessed due to high concentration of parameter in the spiked sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:00|916|Calcium|502||mg/L|0.30|1.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:00|1034|Chromium|4.7|I|ug/L|4.0|16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:00|1045|Iron|120|U|ug/L|120|480|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:08|927|Magnesium|1.52E+03||mg/L|4.0|16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:00|1082|Strontium|8.94E+03||ug/L|8.0|32|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:08|1102|Tin|300|U|ug/L|300|1.2E+03|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:00|1152|Titanium|3.0|U|ug/L|3.0|12|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:00|1087|Vanadium|8.0|U|ug/L|8.0|32|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|02-JUN-2023|02:00|1092|Zinc|20|U|ug/L|20|80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeg er|Batch matrix spike recoveries for calcium, magnesium and strontium are unavailable because of high analyte concentration in the QC sample. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|01:21|1105|Aluminum|20|U|ug/L|20|80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1097|Antimony|0.50|U|ug/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1002|Arsenic|2.9||ug/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|01:21|1012|Beryllium|0.040|U|ug/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1027|Cadmium|0.20|U|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1037|Cobalt|0.20|U|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1042|Copper|9.9||ug/L|4.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1051|Lead|2.0|U|ug/L|2.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1055|Manganese|14.4||ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1062|Molybdenum|9.1||ug/L|1.5|6.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1067|Nickel|5.0|U|ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1147|Selenium|2.0|U|ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|19:09|1077|Silver|0.050|U|ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023. RQ-2023-05-15-28|TLH-2023-05-23-32|2411823|PORT OF THE ISLANDS MARINA|G1SD0130|22-MAY-2023|10:05|01-JUN-2023|00:04|1059|Thallium|1.0|U|ug/L|1.0|4.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|30-MAY-2023|11:35|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeg er|The copper result was confirmed in the undigested sample on 06/01/2023.