REQUEST_ID|JOB_ID|SAMPLE_ID|SAMPLE_SITE|FIELD_ID|SAMPLE_DATE|SAMPLE_TIME|ANALYSIS_DATE|ANALYSIS_TIME|PARAM_CODE|PARAM_NAME|RESULT|VALUE_QUAL|UOM|MDL|PQL|PREP_METHOD|PREP_DESC|PREP_DATE|PREP_TIME|ANALYSIS_METHOD|SAMPLER|LAB_COMMENTS RQ-2023-08-07-61|TLH-2023-08-15-37|2430834|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|17-AUG-2023|09:13||Total Alkalinity|85||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430834|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|15-AUG-2023|13:23|76|Turbidity|3.6||NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430834|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|17-AUG-2023|22:10|940|Chloride|20||mg Cl/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430834|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|15-AUG-2023|14:18|80|Color (true)|260||PCU|5.0|12|||||DEP SOP: NU-094-1|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430834|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|17-AUG-2023|09:13|951|Fluoride|0.12||mg F/L|0.025|0.10|||||SM 4500-F- C-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430834|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|17-AUG-2023|22:10|945|Sulfate|5.0||mg SO4/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Monica Jaeger|Sulfate: Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-37|2430834|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|16:04|70300|TDS|196||mg/L|15|25|||||SM 2540 C-2015|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430834|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|16:04|530|TSS|5|I|mg/L|2.0|10|||||SM 2540 D-2015|Nicole Reistad, Monica Jaeger|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-37|2430835|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|17-AUG-2023|09:28||Total Alkalinity|270||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430835|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|15-AUG-2023|13:24|76|Turbidity|2.8||NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430835|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|17-AUG-2023|22:33|940|Chloride|54||mg Cl/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430835|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|15-AUG-2023|14:19|80|Color (true)|89||PCU|2.5|6.0|||||DEP SOP: NU-094-1|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430835|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|17-AUG-2023|09:28|951|Fluoride|0.57||mg F/L|0.025|0.10|||||SM 4500-F- C-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430835|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|17-AUG-2023|22:33|945|Sulfate|49||mg SO4/L|0.40|1.0|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Monica Jaeger|Sulfate: Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-37|2430835|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|16:04|70300|TDS|492||mg/L|15|25|||||SM 2540 C-2015|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430835|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|16:04|530|TSS|6|I|mg/L|2.0|10|||||SM 2540 D-2015|Nicole Reistad, Monica Jaeger|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-37|2430836|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|22-AUG-2023|12:52|610|Ammonia-N|0.021||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430836|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|29-AUG-2023|10:38|630|NO2NO3-N|0.10||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430836|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|17-AUG-2023|14:14|665|Total-P|0.13||mg P/L|0.010|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|16-AUG-2023|16:02|EPA 365.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430836|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|24-AUG-2023|12:07|625|Kjeldahl Nitrogen|1.3||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|23-AUG-2023|11:43|EPA 351.2 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430836|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|16-AUG-2023|18:42|680|Organic Carbon|27||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430837|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|22-AUG-2023|12:28|610|Ammonia-N|0.034||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430837|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|29-AUG-2023|10:39|630|NO2NO3-N|0.077||mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430837|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|17-AUG-2023|14:15|665|Total-P|0.34||mg P/L|0.010|0.050|365.1 (MARCH 1983)|Automated, ascorbic acid|16-AUG-2023|16:02|EPA 365.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430837|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|24-AUG-2023|12:15|625|Kjeldahl Nitrogen|1.1||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|23-AUG-2023|11:43|EPA 351.2 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430837|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|16-AUG-2023|18:56|680|Organic Carbon|15||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430838|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|09:40||Total Alkalinity|4.8||mg CaCO3/L|0.65|2.5|||||SM 2320 B-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430838|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|15-AUG-2023|13:28|76|Turbidity|1.3||NTU|0.10|1.0|||||EPA 180.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430838|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|22:48|940|Chloride|9.5||mg Cl/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430838|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|15-AUG-2023|14:20|80|Color (true)|740||PCU|18|42|||||DEP SOP: NU-094-1|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430838|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|09:40|951|Fluoride|0.060|I|mg F/L|0.025|0.10|||||SM 4500-F- C-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430838|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|22:48|945|Sulfate|0.21|I|mg SO4/L|0.20|0.50|||||EPA 300.0 Rev. 2.1|Nicole Reistad, Monica Jaeger|Sulfate: Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-37|2430838|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|18-AUG-2023|16:04|70300|TDS|138||mg/L|15|25|||||SM 2540 C-2015|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430838|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|18-AUG-2023|16:04|530|TSS|3|I|mg/L|2.0|10|||||SM 2540 D-2015|Nicole Reistad, Monica Jaeger|Batch relative percent difference is unavailable because of low analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-37|2430839|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|12:29|610|Ammonia-N|0.026||mg N/L|0.0020|0.0050|||||EPA 350.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430839|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|29-AUG-2023|10:52|630|NO2NO3-N|0.004|U|mg N/L|0.0040|0.010|||||EPA 353.2 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430839|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|17:55|665|Total-P|0.041||mg P/L|0.0020|0.0050|365.1 (MARCH 1983)|Automated, ascorbic acid|16-AUG-2023|16:02|EPA 365.1 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430839|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|24-AUG-2023|12:17|625|Kjeldahl Nitrogen|1.7||mg N/L|0.080|0.20|351.2 (MARCH 1983)|Preparation of samples for total kjeldahl nitrogen analysis|23-AUG-2023|11:43|EPA 351.2 Rev. 2.0|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-37|2430839|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|16-AUG-2023|19:11|680|Organic Carbon|48||mg C/L|0.50|1.0|||||SM 5310 B-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|16-AUG-2023|12:12||AMPA|0.30|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|16-AUG-2023|05:35||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|16-AUG-2023|12:12||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|16-AUG-2023|12:12||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|16-AUG-2023|12:12||Glyphosate|0.15|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|16-AUG-2023|05:35||Sucralose|0.014|I|ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05|39730|2,4-D|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Bentazon|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Dinotefuran|0.027||ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Fenuron|0.032|U|ug/L|0.032|0.13|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Ibuprofen|0.20|U|ug/L|0.20|0.80|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Imazapyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Imidacloprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||MCPP|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05|39760|Silvex|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430880|JACKS BRANCH|G3SD0176|14-AUG-2023|10:45|18-AUG-2023|22:05||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|16-AUG-2023|13:18||AMPA|0.91||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|16-AUG-2023|06:45||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|16-AUG-2023|13:18||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|16-AUG-2023|13:18||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|16-AUG-2023|13:18||Glyphosate|9.9||ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|16-AUG-2023|06:45||Sucralose|0.072||ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24|39730|2,4-D|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Bentazon|0.0046||ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Clothianidin|0.0037|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Fenuron|0.032|U|ug/L|0.032|0.13|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Fluridone|9.3E-04|I|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Ibuprofen|0.20|U|ug/L|0.20|0.80|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Imazapyr|0.088||ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Imidacloprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||MCPP|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24|39760|Silvex|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Thiamethoxam|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430881|FORT SIMMONS BRANCH|G3SD0177|14-AUG-2023|11:05|18-AUG-2023|22:24||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06||3-Hydroxycarbofuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06||Aldicarb|0.020|U|ug/L|0.020|0.080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06||Aldicarb Sulfone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06||Aldicarb Sulfoxide|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06|39750|Carbaryl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06|81405|Carbofuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06||Methiocarb|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06|39051|Methomyl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06||Oxamyl|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430882|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|19-AUG-2023|13:06||Propoxur|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|18-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|16-AUG-2023|13:44||AMPA|0.15|I|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|16-AUG-2023|07:13||Acesulfame K|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|16-AUG-2023|13:44||Endothall|0.25|U|ug/L|0.25|1.0|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|16-AUG-2023|13:44||Glufosinate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|16-AUG-2023|13:44||Glyphosate|0.10|U|ug/L|0.10|0.40|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|16-AUG-2023|07:13||Sucralose|0.024|I|ug/L|0.010|0.040|LC-FILTER|Filtration of samples prior to analysis|16-AUG-2023|04:30|EPA 8321B|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43|39740|2,4,5-T|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43|39730|2,4-D|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Acetaminophen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Acetamiprid|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Afidopyropen|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Bentazon|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Benzovindiflupyr|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Carbamazepine|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Clothianidin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Dinotefuran|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Diuron|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Fenuron|0.032|U|ug/L|0.032|0.13|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Fluridone|8.0E-04|U|ug/L|8.0E-04|0.0032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Hydrocodone|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Ibuprofen|0.20|U|ug/L|0.20|0.80|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Imazapyr|0.0085|I|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Imidacloprid|0.0067|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Linuron|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||MCPP|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Mandestrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Naproxen|0.0080|U|ug/L|0.0080|0.032|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Primidone|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Pyraclostrobin|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43|39760|Silvex|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Thiamethoxam|0.0024|I|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Tolfenpyrad|0.0020|U|ug/L|0.0020|0.0080|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-43|2430883|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|22:43||Triclopyr|0.0040|U|ug/L|0.0040|0.016|3535A|Prep for herbicides and carbamates|16-AUG-2023|13:00|EPA 8321B|Nicole Reistad, Monica Jaeger|MS accuracy for some analytes could not be assessed due to a high concentration of some parameters in the spiked sample. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|07:35||Chlordane|2.0|U|ng/L|2.0|6.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8276|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|07:35||Toxaphene|15|U|ng/L|15|38|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8276|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|00:13||PCB-1016|2.0|U|ng/L|2.0|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8270E|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|00:13||PCB-1221|2.0|U|ng/L|2.0|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8270E|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|00:13||PCB-1232|2.0|U|ng/L|2.0|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8270E|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|00:13||PCB-1242|2.0|U|ng/L|2.0|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8270E|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|00:13||PCB-1248|2.0|U|ng/L|2.0|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8270E|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|00:13||PCB-1254|2.0|U|ng/L|2.0|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8270E|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|00:13||PCB-1260|2.0|U|ng/L|2.0|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|17-AUG-2023|08:30|EPA 8270E|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39330|Aldrin|0.66|UQ|ng/L|0.66|3.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39337|Alpha-BHC|0.10|UQ|ng/L|0.10|0.51|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Alpha-Chlordane|0.20|UQ|ng/L|0.20|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39338|Beta-BHC|0.10|UQ|ng/L|0.10|0.51|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Beta-Cyfluthrin|1.3|UQ|ng/L|1.3|6.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Bifenthrin|0.51|UQ|ng/L|0.51|2.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|70314|Chlorothalonil|3.7|UQ|ng/L|3.7|18|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Cis-Nonachlor|0.20|UQ|ng/L|0.20|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|3781|Cypermethrin|1.5|UQ|ng/L|1.5|7.7|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39310|DDD-p,p'|0.26|UQ|ng/L|0.26|1.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39320|DDE-p,p'|0.20|UQ|ng/L|0.20|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39300|DDT-p,p'|0.82|UQ|ng/L|0.82|4.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Dacthal|0.15|UQ|ng/L|0.15|0.77|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|34259|Delta-BHC|0.41|UQ|ng/L|0.41|2.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Deltamethrin|1.3|UQ|ng/L|1.3|6.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Dichlobenil|0.26|UQ|ng/L|0.26|1.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Dicofol|1.3|UQ|ng/L|1.3|6.4|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39380|Dieldrin|0.41|UQ|ng/L|0.41|2.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|34361|Endosulfan I|0.41|UQ|ng/L|0.41|2.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|34356|Endosulfan II|0.92|UQ|ng/L|0.92|4.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|34351|Endosulfan Sulfate|0.31|UQ|ng/L|0.31|1.5|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39390|Endrin|0.92|UQ|ng/L|0.92|4.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|34366|Endrin Aldehyde|0.77|UQJ|ng/L|0.77|3.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Endrin Ketone|0.41|UQ|ng/L|0.41|2.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Esfenvalerate|0.77|UQ|ng/L|0.77|3.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Ethalfluralin|0.15|UQ|ng/L|0.15|0.77|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Fenpropathrin|0.26|UQ|ng/L|0.26|1.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39340|Gamma-BHC|0.13|UQJ|ng/L|0.13|0.64|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Gamma-Chlordane|0.20|UQ|ng/L|0.20|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39410|Heptachlor|0.20|UQ|ng/L|0.20|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39420|Heptachlor Epoxide|0.26|UQ|ng/L|0.26|1.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Hexachlorobenzene|1.0|UQ|ng/L|1.0|5.1|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Kepone|14|UQJ|ng/L|14|69|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Lambda-Cyhalothrin|0.77|UQ|ng/L|0.77|3.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||MGK-264|0.20|UQ|ng/L|0.20|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Methoprene|0.77|UQ|ng/L|0.77|3.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39480|Methoxychlor|0.31|UQ|ng/L|0.31|1.5|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|39755|Mirex|0.36|UQ|ng/L|0.36|1.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Oxychlordane|0.31|UQ|ng/L|0.31|1.5|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|79191|Permethrin|1.6|UQ|ng/L|1.6|8.2|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Phenothrin|0.92|UQ|ng/L|0.92|4.6|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Piperonyl Butoxide|0.15|UQ|ng/L|0.15|0.77|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Prallethrin|2.0|UQ|ng/L|2.0|10|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Tau-Fluvalinate|0.26|UQ|ng/L|0.26|1.3|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Tetramethrin|0.77|UQ|ng/L|0.77|3.8|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Trans-Nonachlor|0.20|UQ|ng/L|0.20|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02||Triclosan Methyl|0.15|UQ|ng/L|0.15|0.77|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430884|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|05-SEP-2023|23:02|81284|Trifluralin|0.20|UQ|ng/L|0.20|1.0|3535A (GC)|Prep for organochlorine pesticides in water matrix by GC/MS-SIM|29-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Sample expired for preparation due to need for re-extraction. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Acetochlor|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Alachlor|0.41|U|ng/L|0.41|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|82184|Ametryn|1.1|U|ng/L|1.1|5.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|39033|Atrazine|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Atrazine Desethyl|1.3|U|ng/L|1.3|6.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Azinphos Methyl|3.1|U|ng/L|3.1|15|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Azoxystrobin|0.41|U|ng/L|0.41|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Bromacil|12||ng/L|0.62|3.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Butylate|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Caffeine|7.7|U|ng/L|7.7|39|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Carbophenothion|0.51|U|ng/L|0.51|2.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Carfentrazone Ethyl|0.15|U|ng/L|0.15|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Chlorfenapyr|0.31|U|ng/L|0.31|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|38932|Chlorpyrifos Ethyl|0.31|U|ng/L|0.31|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|38740|Chlorpyrifos Methyl|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Coumaphos|1.1|U|ng/L|1.1|5.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Cyanazine|5.1|U|ng/L|5.1|26|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Cyprodinil|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Demeton|3.6|U|ng/L|3.6|18|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Diazinon|0.13|U|ng/L|0.13|0.64|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Difenoconazole|0.62|U|ng/L|0.62|3.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Dimethenamid|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Dimethomorph|0.31|UJ|ng/L|0.31|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|81888|Disulfoton|0.62|U|ng/L|0.62|3.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Dithiopyr|1.0|U|ng/L|1.0|5.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||EPTC|0.51|U|ng/L|0.51|2.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|39398|Ethion|0.31|U|ng/L|0.31|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|81758|Ethoprop|0.13|U|ng/L|0.13|0.64|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Etridiazole|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fenamiphos|0.46|U|ng/L|0.46|2.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fenbuconazole|0.51|U|ng/L|0.51|2.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fipronil|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fipronil Desulfinyl|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fipronil Sulfide|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fipronil Sulfone|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fluazifop-P-butyl|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fludioxonil|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Flumioxazin|3.1|U|ng/L|3.1|15|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Flutolanil|0.53||ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fluxapyroxad|0.26|U|ng/L|0.26|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Fonofos|0.15|U|ng/L|0.15|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|38815|Hexazinone|81||ng/L|0.51|2.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Imazalil|0.67|U|ng/L|0.67|3.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Iprodione|0.51|U|ng/L|0.51|2.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Loratadine|0.31|U|ng/L|0.31|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|39530|Malathion|0.36|U|ng/L|0.36|1.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Metalaxyl|1.6|I|ng/L|0.51|2.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Metolachlor|0.77|U|ng/L|0.77|3.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|81408|Metribuzin|0.41|U|ng/L|0.41|2.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|39610|Mevinphos|1.0|U|ng/L|1.0|5.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Molinate|0.26|U|ng/L|0.26|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Myclobutanil|0.36|U|ng/L|0.36|1.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Naled|2.6|U|ng/L|2.6|13|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Napropamide|0.72|U|ng/L|0.72|3.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|78064|Norflurazon|19||ng/L|1.0|5.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Oxadiazon|0.36|U|ng/L|0.36|1.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Oxyfluorfen|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Parathion Ethyl|0.15|U|ng/L|0.15|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Parathion Methyl|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Pendimethalin|0.77|U|ng/L|0.77|3.9|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Phenytoin|5.4|U|ng/L|5.4|27|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|46313|Phorate|0.26|U|ng/L|0.26|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Prodiamine|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|39056|Prometon|3.1|U|ng/L|3.1|15|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|39057|Prometryn|0.36|U|ng/L|0.36|1.8|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Pronamide|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Propanil|0.10|U|ng/L|0.10|0.51|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Propargite|0.82|U|ng/L|0.82|4.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Propiconazole|0.62|U|ng/L|0.62|3.1|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Pyraflufen Ethyl|0.31|U|ng/L|0.31|1.5|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Pyridaben|1.4|U|ng/L|1.4|7.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Pyriproxyfen|0.26|U|ng/L|0.26|1.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|39055|Simazine|0.26|U|ng/L|0.26|1.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Stirophos|0.41|U|ng/L|0.41|3.3|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Sulfentrazone|1.4|U|ng/L|1.4|7.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Tebuconazole|1.4|U|ng/L|1.4|7.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24|82088|Terbufos|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Terbuthylazine|0.21|U|ng/L|0.21|1.0|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Thiobencarb|0.51|U|ng/L|0.51|2.6|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|16:24||Triadimefon|0.15|U|ng/L|0.15|0.77|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|MS accuracy for bromacil and norflurazon not assessed due to high content of these parameters in the sample spiked. Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||2-Ethylhexyl 2,3,4,5-tetrabromobenzoate (EHTBB)|12|U|ng/L|12|37|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Avobenzone|100|U|ng/L|100|310|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Dechlorane 602|5.1|UJ|ng/L|5.1|15|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Dechlorane 603|4.1|U|ng/L|4.1|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Dechlorane Plus|31|U|ng/L|31|92|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Hexabromobenzene|6.2|U|ng/L|6.2|18|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Octinoxate|150|U|ng/L|150|460|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Oxybenzone|10|U|ng/L|10|31|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||PBB-153|8.2|U|ng/L|8.2|25|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||PBDE-47|4.1|U|ng/L|4.1|12|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||PBDE-99|5.1|U|ng/L|5.1|15|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Pentabromotoluene|3.1|U|ng/L|3.1|9.2|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Tetradecachloro-m-terphenyl|7.7|U|ng/L|7.7|23|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Tri-o-cresyl Phosphate|6.2|U|ng/L|6.2|18|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Tris(1,3-dichloro-2-propyl) phosphate (TDCPP)|2.6|U|ng/L|2.6|7.7|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Tris(1-chloro-2-propyl) phosphate (TCPP)|15|U|ng/L|15|46|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-45|2430885|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|18-AUG-2023|20:37||Tris(2-chloroethyl) phosphate (TCEP)|72|U|ng/L|72|220|3510C (TQ)|Separatory funnel liquid-liquid extraction|16-AUG-2023|08:00|EPA 8270E|Nicole Reistad, Monica Jaeger|Refer to the Lab Analysis Report for an explanation of QC Codes. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|46570|Hardness|24.9||mg/L|0.35|1.4|||||SM 2340 B-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|916|Calcium|6.55||mg/L|0.075|0.30|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|1045|Iron|1.65E+03||ug/L|30|120|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|927|Magnesium|2.07||mg/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|937|Potassium|0.30|U|mg/L|0.30|1.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|929|Sodium|6.2||mg/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|1082|Strontium|32.0||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|1102|Tin|3.0|U|ug/L|3.0|12|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|1152|Titanium|1.3|I|ug/L|0.75|3.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|1087|Vanadium|2.0|U|ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|17-AUG-2023|18:34|1092|Zinc|5.0|U|ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1105|Aluminum|198||ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1097|Antimony|0.050|U|ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1002|Arsenic|1.39||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1007|Barium|6.95||ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|23-AUG-2023|15:52|1012|Beryllium|0.020|I|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1022|Boron|20.2||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1027|Cadmium|0.020|U|ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1034|Chromium|0.64|I|ug/L|0.40|1.6|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|25-AUG-2023|16:09|1037|Cobalt|0.270||ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1042|Copper|0.40|U|ug/L|0.40|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|23-AUG-2023|15:52|1051|Lead|0.44||ug/L|0.20|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1055|Manganese|17.7||ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1062|Molybdenum|0.15|U|ug/L|0.15|0.60|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|25-AUG-2023|16:09|1067|Nickel|0.50|U|ug/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1147|Selenium|0.20|U|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1077|Silver|0.010|U|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430886|CHAPARRALSLOUGHATSR29|G3SD0224|14-AUG-2023|09:45|22-AUG-2023|21:15|1059|Thallium|0.10|U|ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|46570|Hardness|68.0||mg/L|0.35|1.4|||||SM 2340 B-2011|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|916|Calcium|20.5||mg/L|0.075|0.30|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|1045|Iron|1.41E+03||ug/L|30|120|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|927|Magnesium|4.05||mg/L|0.040|0.16|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|937|Potassium|2.1||mg/L|0.30|1.2|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|929|Sodium|14.8||mg/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|1082|Strontium|266||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|1102|Tin|3.0|U|ug/L|3.0|12|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|1152|Titanium|1.1|I|ug/L|0.75|3.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|1087|Vanadium|2.0|U|ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|17-AUG-2023|18:42|1092|Zinc|5.0|U|ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|16-AUG-2023|12:35|EPA 200.7 Rev. 4.4|Nicole Reistad, Monica Jaeger|Batch matrix spike recoveries for calcium and sodium are unavailable for one of two spiked samples because of high analyte concentration in the QC sample. RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1105|Aluminum|195||ug/L|5.0|20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1097|Antimony|0.075|I|ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1002|Arsenic|1.40||ug/L|0.050|0.20|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1007|Barium|14.9||ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|23-AUG-2023|15:58|1012|Beryllium|0.034|I|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1022|Boron|27.6||ug/L|2.0|8.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1027|Cadmium|0.020|U|ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1034|Chromium|0.93|I|ug/L|0.40|1.6|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|25-AUG-2023|16:16|1037|Cobalt|0.346||ug/L|0.020|0.080|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1042|Copper|0.56|I|ug/L|0.40|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|23-AUG-2023|15:58|1051|Lead|0.45||ug/L|0.20|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1055|Manganese|36.6||ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1062|Molybdenum|0.31|I|ug/L|0.15|0.60|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|25-AUG-2023|16:16|1067|Nickel|0.84|I|ug/L|0.50|2.0|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1147|Selenium|0.20|U|ug/L|0.20|0.80|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1077|Silver|0.010|U|ug/L|0.010|0.040|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger| RQ-2023-08-07-61|TLH-2023-08-15-46|2430887|BEE BRANCH AT CR78|G3SD0226|14-AUG-2023|10:15|22-AUG-2023|21:25|1059|Thallium|0.10|U|ug/L|0.10|0.40|200.2|Sample prep procedure for spectrochemical determination of total recoverable elements|21-AUG-2023|12:45|EPA 200.8 Rev. 5.4|Nicole Reistad, Monica Jaeger|